CAUTION
20. After completion of installation or service, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant
contacts with fire.
21. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with fire.
22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.
23. Must not use other parts except original parts describe in catalog and manual.
24. Using of refrigerant other than the specified type may cause product damage, burst and injury etc.
1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the
unit, it may cause fire.
2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage
the furniture.
3. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare
may break and cause refrigerant gas leakage.
4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury.
5. Select an installation location which is easy for maintenance.
6. Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use
a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F / 600°C).
7. Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following
methods.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries,
permanent connection of this room air conditioner to the power supply is prohibited.
i. Power supply connection to the receptacle using a power plug.
Use an approved 15/16A (1.0 ~ 1.5HP) or 16A (2.0HP) or 20A (2.5HP), 25A (3.0HP) power plug with earth pin for the connection to the
socket.
ii. Power supply connection to a circuit breaker for the permanent connection.
Use an approved 16A (1.0 ~ 2.0HP) or 20A (2.5HP), 25A (3.0HP) circuit breaker for the permanent connection. It must be a double pole
switch with a minimum 3.0 mm contact gap.
8. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take
care of the liquid refrigerant, it may cause frostbite.
9. Installation or servicing work: It may need two people to carry out the installation or servicing work.
10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
11. Do not sit or step on the unit, you may fall down accidentally.
12. Do not touch the sharp aluminum fins or edges of metal parts.
If you are required to handle sharp parts during installation or servicing, please wear hand glove.
Sharp parts may cause injury.
Summary of Contents for CS-PC12QKH
Page 16: ...16 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 17: ...17 5 Dimensions 5 1 Indoor Unit 5 1 1 CS PC9QKH CS PC12QKH ...
Page 18: ...18 5 1 2 CS PC18QKH CS PC24QKH CS PC28QKH ...
Page 19: ...19 5 2 Outdoor Unit 5 2 1 CU PC9QKH CU PC12QKH 5 2 2 CU PC18QKH ...
Page 20: ...20 5 2 3 CU PC24QKH 5 2 4 CU PC28QKH ...
Page 21: ...21 6 Refrigeration Cycle Diagram ...
Page 22: ...22 7 Block Diagram 7 1 CS PC9QKH CU PC9QKH CS PC12QKH CU PC12QKH CS PC18QKH CU PC18QKH ...
Page 23: ...23 7 2 CS PC24QKH CU PC24QKH ...
Page 24: ...24 7 3 CS PC28QKH CU PC28QKH ...
Page 29: ...29 9 Electronic Circuit Diagram 9 1 CS PC9QKH CU PC9QKH CS PC12QKH CU PC12QKH ...
Page 30: ...30 9 2 CS PC18QKH CU PC18QKH ...
Page 31: ...31 9 3 CS PC24QKH CU PC24QKH ...
Page 32: ...32 9 4 CS PC28QKH CU PC28QKH ...
Page 34: ...34 10 1 1 2 CS PC18QKH ...
Page 35: ...35 10 1 1 3 CS PC24QKH ...
Page 36: ...36 10 1 1 4 CS PC28QKH ...
Page 52: ...52 12 2 5 Wire Stripping and Connecting Requirement ...
Page 58: ...58 13 1 2 Cooling Operation Time Diagram For PC18 24 28QKH ...
Page 60: ...60 13 2 2 Soft Dry Operation Time Diagram For PC18 24 28QKH ...
Page 73: ...73 17 1 1 3 To Remove Discharge Grille ...
Page 74: ...74 17 1 1 4 To Remove Control Board 17 1 1 5 To Remove Cross Flow Fan and Indoor Fan Motor ...
Page 75: ...75 ...
Page 77: ...77 17 2 1 3 To Remove Main Electronic Controller Fig 3 ...
Page 78: ...78 17 2 1 4 To Remove Discharge Grille Fig 6 17 2 1 5 To Remove Control Board Fig 7 ...
Page 79: ...79 17 2 1 6 To Remove Cross Flow Fan and Indoor Fan Motor Fig 8 Fig 9 ...
Page 80: ...80 Fig 10 Fig 11 ...
Page 81: ...81 18 Technical Data 18 1 Thermostat Characteristics Cooling Soft Dry ...