40
11.7 CONNECTING THE CABLE TO THE INDOOR UNIT
Remove the mounting screw, remove the control
box cover, and then connect the wires by
following the procedure given in the illustration.
Connecting cable between indoor unit and
outdoor unit shall be approved polychloroprene
sheathed 4 x 1.5 mm
2
flexible cord, type
designation 60245 IEC 57 or heavier cord.
Secure the connecting cable onto the control
board with the holder (clamper).
Ensure the colour of wires of outdoor unit and the
terminal Nos. are the same to the indoor’s
respectively.
Earth wire shall be Yellow/Green (Y/G) in colour
and longer than other AC wires for safety reason.
11.7.1 WIRE STRIPPING AND CONNECTING REQUIREMENT
Summary of Contents for CS-ME9PB4EA
Page 28: ...28 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control...
Page 29: ...29 5 Dimensions 5 1 Indoor Unit...
Page 30: ...30 6 Refrigeration Cycle Diagram...
Page 31: ...31 7 Block Diagram...
Page 32: ...32 8 Wiring Connection Diagram 8 1 Indoor Unit...
Page 33: ...33 9 Electronic Circuit Diagram 9 1 Indoor Unit...
Page 34: ...34 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board...
Page 81: ...81 16 Exploded View and Replacement Parts List 16 1 Indoor Unit...