9.13.1. Oxygen Enrich System Figure
9.13. Oxygen Enrich Operation
9.13.2. Indoor Fan Control
Single Oxygen Enrich operation
1. Manual fan speed ............. Not available for the remote controller.
2. Automatic fan speed ............. Fixed.
Revolution (rpm)
Normal Fan Speed (AUTO)
480
•
•
•
•
When used in common with other modes, it will be followed by other modes.
Order of priority: Cooling, Dry and Heating > Ion > Oxygen Enrich
•
•
•
•
Powerful and Quiet operations are not accepted at the Oxygen Enrich Operation mode.
9.13.3. Indoor Airflow Direction Control
1. Manual and Automatic Airflow Direction ................. Same as Cooling operation.
•
•
•
•
When used in common with other modes, it will be followed by other modes.
Order of priority: Cooling, Dry and Heating > Ion > Oxygen Enrich
9.13.4. Conditions of starting and cancellation
1. ON/OFF by the "Oxygen & Ventilation Selection" Switch on the remote controller
•
•
•
•
When "Oxygen" is selected with the Switch under a condition of Ionizing Air Clearing OFF
→
Single Oxygen Enrich Operation
•
•
•
•
When "Oxygen" is selected with the Switch under a condition of Ionizing Air Clearing ON,
→
Ionizing Air Cl Simultaneous Oxygen Enrich Operation
•
•
•
•
When "Oxygen" is selected with the Switch during Single Oxygen Enrich Operation,
→
Operation is stopped.
•
•
•
•
When "Oxygen" is selected with the Switch during Cooling, Heating, Dry or Ionizing Air Cleaning Operation,
→
Cooling, Heating, Dry or Ionizing Air Cleaning Ope Simultaneous Oxygen Enrich Operation,
•
•
•
•
When "Oxygen" is selected with the Switch during Cooling, Heating, Dry or Ionizing Air Cleaning Ope Simultaneous
Oxygen Enrich Operation,
34
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE
Summary of Contents for CS-HE9DKE
Page 3: ...2 Functions 2 1 Remote Control 3 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 4: ...2 2 Indoor Unit 4 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 5: ...2 3 Outdoor unit 5 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 10: ...4 Dimensions 4 1 Indoor Unit Remote Control 10 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 11: ...4 2 Outdoor Unit 11 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 13: ...6 Block Diagram 13 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 14: ...7 1 Indoor Unit 7 Wiring Diagram 14 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 15: ...7 2 Outdoor Unit 15 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 17: ...17 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 18: ...8 2 Outdoor Unit 18 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 19: ...19 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 39: ...10 Operating Instructions 39 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 40: ...40 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 41: ...41 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 42: ...42 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 43: ...43 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 44: ...44 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...
Page 82: ...CS HE12DKE CU HE12DKE 82 CS HE9DKE CU HE9DKE CS HE12DKE CU HE12DKE...