31
12.1.5 Automatic
Operation
This mode can be set using remote control and the operation is decided by remote control setting temperature,
remote control operation mode and indoor intake air temperature.
During operation mode judgment, indoor fan motor (with speed of Lo-) is running for 30 seconds to detect the
indoor intake air temperature.
Every 10 minutes, the indoor temperature is judged.
For the 1st judgment
o
If indoor intake temperature - remote control setting temperature
≥
3.6°F, COOL mode is decided.
o
If
-3.6°F
≤
indoor intake temperature - remote control setting temperature < 3.6°F, DRY mode is decided.
o
If indoor intake temperature - remote control setting temperature < -3.6°F, HEAT mode is decided.
For the 2nd judgment onwards
o
If indoor intake temperature - remote control setting temperature
≥
5.4°F, if previous operate in DRY mode,
then continue in DRY mode. Otherwise COOL mode is decided.
o
If
-3.6°F
≤
indoor intake temperature - remote control setting temperature < 5.4°F, maintain with previous
mode.
o
If indoor intake temperature - remote control setting temperature < -3.6°F, HEAT mode is decided.
12.2 Indoor Fan Motor Operation
12.2.1
Basic Rotation Speed (rpm)
Manual
Fan
Speed
[Cooling, Dry]
o
Fan motor’s number of rotation is determined according to remote control setting.
Remote control
○
○
○
○
○
Tab Hi
Me+
Me
Me-
Lo
[Heating]
o
Fan motor’s number of rotation is determined according to remote control setting.
Remote control
○
○
○
○
○
Tab Shi
Me+
Me
Me-
Lo
Auto Fan Speed
[Cooling, Dry]
o
According to room temperature and setting temperature, indoor fan speed is determined automatically.
o
The indoor fan will operate according to pattern below.
o
During operation, indoor fan motor may stop due to odor prevention.
Summary of Contents for CS-E18NKUA
Page 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 10: ...10 5 Dimensions 5 1 Indoor Unit ...
Page 11: ...11 5 2 Outdoor Unit ...
Page 12: ...12 6 Refrigeration Cycle Diagram ...
Page 13: ...13 7 Block Diagram ...
Page 14: ...14 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 15: ...15 8 2 Outdoor Unit ...
Page 16: ...16 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 17: ...17 9 2 Outdoor Unit ...
Page 18: ...18 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 19: ...19 10 1 2 Power Printed Circuit Board 10 1 3 Indicator and Receiver Printed Circuit Board ...
Page 20: ...20 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Page 21: ...21 10 2 2 Noise Filter Printed Circuit Board ...
Page 45: ...45 15 3 Error Code Table ...
Page 68: ...68 16 1 1 2 To remove discharge grille ...
Page 69: ...69 16 1 1 3 To remove control board 16 1 1 4 To remove cross flow fan and indoor fan motor ...
Page 70: ...70 ...