![Panasonic CS-E12PKEW Service Manual Download Page 15](http://html.mh-extra.com/html/panasonic/cs-e12pkew/cs-e12pkew_service-manual_256819015.webp)
15
Indoor CS-E24PKEW
CS-E28PKES
Model
Outdoor CU-E24PKE
CU-E28PKE
Performance Test Condition
EUROVENT
EUROVENT
Phase, Hz
Single, 50
Single, 50
Power Supply
V 230
230
Min. Mid. Max. Min. Mid. Max.
kW
0.98 6.80 8.10 0.98 7.65 8.60
BTU/h
3340 23200 27600 3340 26100 29300
Capacity
Kcal/h
840 5850 6970 840 6580 7400
Running
Current
A
- 9.5 - - 11.5 -
Input
Power
W
380 2.08k 2.65k 380 2.52k 2.92k
Annual
Consumption kWh
- 1040 - - 1260 -
W/W
2.58 3.27 3.06 2.58 3.04 2.95
BTU/hW 8.79 11.15 10.42 8.79 10.36 10.03
EER
Kcal/hW 2.21 2.81 2.63 2.21 2.61 2.53
Pdesign kW
6.8
7.7
SEER (W/W)
6.1
6.0
Annual
Consumption
kWh 390
449
ErP
Class
A++
A+
Power
Factor
%
– 95 – – 95 –
dB-A
47 / 38 / 35
49 / 38 / 35
Indoor Noise (H / L / QLo)
Power Level dB
63 / –
65 / –
dB-A
52 / –
53 / –
Cooling
Outdoor Noise (H / L)
Power Level dB
66 / –
67 / –
kW
0.98 8.60 9.90 0.98 9.60 11.00
BTU/h
3340 29300 33800 3340 32700 37500
Capacity
Kcal/h
840 7400 8510 840 8260 9460
Running
Current
A
– 11.8 – – 14.6 –
Input
Power
W
450 2.60k 3.13k 450 3.26k 3.70k
W/W
2.18 3.31 3.16 2.18 2.94 2.97
BTU/hW 7.42 11.27 10.80 7.42 10.03 10.14
COP
Kcal/hW 1.87 2.85 2.72 1.87 2.53 2.56
Pdesign kW
5.5
6.0
Tbivalent °C
-10
-10
SCOP (W/W)
3.8
3.6
Annual
Consumption
kWh 2026
2333
ErP
Class
A
A
Power
Factor
%
– 96 – – 97 –
dB-A
47 / 38 / 35
48 / 38 / 35
Indoor Noise (H / L / QLo)
Power Level dB
63 / –
64 / –
dB-A
52 / –
53 / –
Heating
Outdoor Noise (H / L)
Power Level dB
66 / –
67 / –
Low Temp. : Capacity (kW) / I.Power (W) / COP
7.17 / 2.77k / 2.59
7.97 / 3.27k / 2.44
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
6.13 / 2.80k / 2.19
6.77 / 3.42k / 1.98
Max Current (A) / Max Input Power (W)
13.8 / 1.70k
15.5 / 3.70k
Starting Current (A)
11.8
14.6
Summary of Contents for CS-E12PKEW
Page 28: ...28 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 30: ...30 5 1 2 CS E18PK CS E21PK CS E24PK CS E28PK CS XE18PK CS XE21PK ...
Page 31: ...31 5 2 Outdoor Unit 5 2 1 CU E7PKE CU E9PKE 5 2 2 CU E12PKE CU E15PKE ...
Page 32: ...32 5 2 3 CU E18PKE CU E21PKE ...
Page 33: ...33 5 2 4 CU E24PKE CU E28PKE ...
Page 42: ...42 8 1 2 CS E28PKES ...
Page 48: ...48 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 56: ...56 10 1 6 Human Activity Sensor Printed Circuit Board ...
Page 57: ...57 10 2 Outdoor Unit 10 2 1 CU E7PKE ...
Page 58: ...58 10 2 2 CU E9PKE CU E12PKE CU E15PKE ...
Page 59: ...59 10 2 3 CU E18PKE CU E21PKE ...
Page 60: ...60 10 2 4 CU E24PKE CU E28PKE ...
Page 66: ...66 ...
Page 68: ...68 For Gas side piping please refer table and diagram below ...
Page 76: ...76 ...
Page 140: ...140 Figure 3 Figure 4 18 1 1 3 To remove discharge grille Figure 5 ...
Page 142: ...142 Figure 8 Figure 9 ...
Page 143: ...143 Figure 10 ...
Page 145: ...145 18 2 1 3 To remove power electronic controller Figure 13 Figure 14 Figure 15 Figure 16 ...
Page 147: ...147 Figure 20 Figure 21 ...
Page 148: ...148 Figure 22 ...