85
17. Technical
Data
Technical data provided are based on the air conditioner running under free frequency.
17.1 Cool Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C
Voltage: 230V
17.1.1 CS-CE9PKE / CU-CE9PKE
Indoor (°C)
Outdoor DB (°C)
16 25 35
DB WB
TC SHC IP TC SHC IP TC SHC IP
19.0 3037 2366 329 2648 2169 425 2500 2006 545
27
22.0 3257 1820 318 2887 1995 427 2675 1653 548
15.7 2783 2321 337 2349 2128 425 2264 2090 544
23
18.4 2901 1781 331 2647 1570 427 2330 1569 539
13.3 2533 2229 342 2234 2011 432 1976 1872 535
20
15.8 2655 1723 337 2373 1594 429 2066 1523 544
(Dry bulb value based on 46% humidity)
17.1.2 CS-CE12PKE / CU-CE12PKE
Indoor (°C)
Outdoor DB (°C)
16 25 35
DB WB
TC SHC IP TC SHC IP TC SHC IP
19.0 4252 3312 574 3707 3036 741 3500 2892 950
27
22.0 4559 2548 555 4042 2793 745 3745 2314 955
15.7 3896 3249 588 3288 2979 741 3170 2926 948
23
18.4 4062 2494 578 3706 2198 744 3263 2196 940
13.3 3546 3121 596 3128 2815 752 2767 2621 932
20
15.8 3717 2413 587 3322 2232 748 2893 2132 948
(Dry bulb value based on 46% humidity)
17.2 Heat Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C
Voltage: 230V
17.2.1 CS-CE9PKE / CU-CE9PKE
Indoor (°C)
Outdoor WB (°C)
-15/-16 -7/-8 2/1
7/6 12/11
DB
TC IP TC IP TC IP TC IP TC IP
24 2355 1160 3175 1294 3607 1236 3356 790 3630 828
20 2388 1103 3220 1230 3700 1190 3400 740 3773 770
16 2459 1046 3316 1166 3729 1125 3658 742 4029 768
17.2.2 CS-CE12PKE / CU-CE12PKE
Indoor (°C)
Outdoor WB (°C)
-15/-16 -7/-8 2/1
7/6 12/11
DB
TC IP TC IP TC IP TC IP TC IP
24 3173 1618 3944 1946 4660 1828 3948 1057 4271 1108
20 3218 1538 4000 1850 4780 1760 4000 990 4439 1030
16 3314 1458 4120 1754 4818 1664 4304 992 4740 1027
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP
- Input Power (kW)