8
Indoor CS-CE12PKE
Model
Outdoor
CU-CE12PKE
Performance Test Condition
EUROVENT
Phase, Hz
Single, 50
Power Supply
V 230
Min.
Mid.
Max.
kW
0.85 3.50 4.00
BTU/h 2900
11900
13600
Capacity
kcal/h 730
3010
3440
Running Current
A
–
4.40
–
Input Power
W
195
950
1.16k
Annual
Consumption
kWh
– 475 –
W/W
4.36 3.68 3.45
BTU/hW
14.87 12.53 11.72
EER
kcal/hW
3.74 3.17 2.97
Pdesign kW
3.5
SEER (W/W)
6.4
Annual
Consumption
kWh 191
ErP
Class
A++
Power
Factor
%
– 94 –
dB-A
42 / 28
Indoor Noise (H / L)
Power Level dB
58 / -
dB-A
48 / -
Cooling
Outdoor Noise (H / L)
Power Level dB
63 / -
kW
0.85 4.00 6.60
BTU/h 2900
13600
22500
Capacity
kcal/h 730
3440
5680
Running Current
A
–
4.60
–
Input Power
W
190
990
1.99k
W/W
4.47 4.04 3.32
BTU/hW
15.26 13.74 11.31
COP
kcal/hW
3.84 3.47 2.85
Pdesign kW
3.6
Tbivalent °C
-10
SCOP (W/W)
3.8
Annual
Consumption
kWh 1326
ErP
Class
A
Power
Factor
%
– 94 –
dB-A
42 / 33
Indoor Noise (H / L)
Power Level dB
58 / -
dB-A
50 / -
Heating
Outdoor Noise (H / L)
Power Level dB
65 / -
Low Temp. : Capacity (kW) / I. Power (W) / COP
4.78 / 1.76k / 2.72
Extr Low Temp. : Capacity (kW) / I. Power (W) / COP
4.00 / 1.85k / 2.16
Max Current (A) / Max Input Power (W)
8.8 / 1.99k
Starting Current (A)
4.60