– 40 –
MAC9512086C2
CS-C73KE
Technical Data
L
L
L
L
L
Operation characteristics
CS-C93KE / CU-C93KE
•
Piping Length Characteristic
•
Cooling Characteristic
•
Cooling Characteristic
• Piping Length Characteristic
CS-C123KE / CU-C123KE
30 32 34 36 38 40 42 44
OUTDOOR ROOM TEMPERATURE (
°
C)
[Condition] Room temperature: 27/19
°
C
Cooling operation: At High fan
Piping length: 7.5 m
4.0
3.5
3.0
2.5
16
15
14
13
0.60
0.55
0.50
3.0
2.8
2.6
2.4
230V
220V
I: Q:
Current (A)
-
Cooling Capacity (kW)
-
LP: O: Outlet
Gas Side Piping Pressure (MPa)
Air Temperature (
°
C)
30 32 34 36 38 40 42 44
OUTDOOR ROOM TEMPERATURE (
°
C)
[Condition] Room temperature: 27/19
°
C
Cooling operation: At High fan
Piping length: 7.5 m
6.0
5.5
5.0
4.5
15
14
13
12
0.55
0.50
0.45
3.8
3.6
3.4
3.2
230V
220V
I: Q:
Current (A)
-
Cooling Capacity (kW)
-
LP: O: Outlet
Gas Side Piping Pressure (MPa)
Air Temperature (
°
C)
PIPING LENGTH (m)
[Condition] Room temperature: 27/19
°
C
Outdoor temperature: 35/34
°
C
Cooling opeartion: At High fan
6.0
5.5
5.0
4.5
15
14
13
12
0.50
0.45
0.40
3.8
3.6
3.4
3.2
230V
220V
I: Q:
Current (A) Cooling Capacity (kW)
LP: O: Outlet
Gas Side Piping Pressure (MPa)
Air Temperature (
°
C)
0
5
10
15
PIPING LENGTH (m)
[Condition] Room temperature: 27/19
°
C
Outdoor temperature: 35/34
°
C
Cooling opeartion: At High fan
4.0
3.5
3.0
2.5
16
15
14
13
0.60
0.55
0.50
3.0
2.8
2.6
2.4
230V
220V
I: Q:
Current (A) Cooling Capacity (kW)
LP: O: Outlet
Gas Side Piping Pressure (MPa)
Air Temperature (
°
C)
0
5
10
Untitled-8
6/28/00, 5:19 PM
40