– 23 –
MAC9512086C2
CS-C73KE
Operation Details
10) Airflow Direction Control
Airflow Direction Auto-Control
•
When set a Airflow Direction Auto-Control with
remote control, the louver swings up and down as
shown in the diagram.
•
The louver does not swing when the Indoor Fan
stops during operation.
•
When stopped with remote control, the discharge
vent is closed with the louver.
36
°
61
°
Lower limit for
Cooling Mode and
Soft Dry Mode
Lower limit for Air Circulation Mode
Horizontal
Swing up and down
Upper limit
*
The left and right airflow direction louvers can be
adjusted manually.
•
When the manual Airflow Direction Selection But-
ton is pressed, the automatic airflow is released
and the airflow direction louver move up and down
in the range shown in the diagram.
The louver can be adjusted by pressing the button
to the desired louver position.
•
When the remote control is used to stop the opera-
tion, the discharge vent is closed with airflow
direction louver.
Airflow Direction Manual Control
• When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time,
so that the room will reach nearly to the set temperature by the desired time.
• For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
• For Automatic mode, the indoor fan will operate at Lo speed for 20 seconds, 15 minutes before the set time to detect
the intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
11) Delay ON Timer Control
Lower limit for Air Circulation Mode
61
°
Horizontal
Upper limit /0
°
The louver can be adjusted with in a range of
“Manual Airflow Direction Selection Button” is
pressed.
*
The left and right airflow direction louvers can be
adjusted manually.
Lower limit for
Cooling Mode and
Soft Dry Mode /36
°
36
°
9
°
18
°
27
°
*
1 There is no swinging while indoor fan is stopped during Cooling and Soft Dry operation.
*
2 In Air Circulation operation, when the intake air temperature reaches set temperature, the airflow direction is
changed from upper limit to lower limit. When the intake air temperature falls to 2
°
C lower than set temperature,
the airflow direction is changed from lower limit to upper limit.
•
Peep sound (Long) will be heard when:-
– Stopping the Air Conditioner using ON/OFF switch.
– Stopping the Sleep Mode.
– Stopping the Powerful Mode.
– Stopping the Economy Mode.
•
Pep sound (Short) will be heard for others.
•
To switch off the peep sound
press the "Auto Operation Button" continuously for 10 seconds or more.
Repeat the above if you want to switch ON the beep sound or switch OFF and ON back the power switch at the indoor
unit.
*
However, if the "Auto Operation Button" have been pressed the Automatic cooling operation will be activated.
If you do not require this operation, you may change it by using the remote control.
12) Remote Control Signal Receiving Sound
Untitled-1
6/28/00, 4:11 PM
23