CS-C73KE
Operation Details
5) Sleep Mode Auto Operation
Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following move-
ment will start to avoid overcooling.
• When the room temperature reaches the setting
temperature or after 1 hour of operation, sleep shift
operation starts and the airflow volume will automati-
cally change to low.
• The setting temperature will be risen by 0.5
°
C at the
start of operation and by 0.5
°
C one hour later.
• The operation will stop after 8 hours.
6) Powerful Mode Operation.
• Purpose of this operation is to obtain the setting temperature quickly.
• When the Powerful Mode is set, the set temperature will be automatically decreased 3
°
C against the present
setting temperature.
This operation automatically will be running under Super High Fan speed.
• Vertical Airflow Direction:-
– In 'manual' setting, the vane will automatically shift down 10
°
lower than previous setting.
– In 'Auto' setting, the vane will automatically swing up and down. However the lower limit will be shifted 10
°
downward.
• Powerful Mode will operate for 15 minutes only.
• Powerful Mode will stop if:-
– Powerful mode button is pressed again.
– Stopped by ON/OFF switch.
– Timer OFF activates.
– Economy mode button is pressed.
– Sleep mode is pressed.
– Operation mode is changed.
7) Economy Mode Operation.
• Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
• When the Economy Mode is set, the set temperature will be automatically increased 0.5
°
C against the present
setting temperature. This operation automatically will be running under Random Fan speed.
(Refer operation detail no. 9 )
• Vertical Airflow Direction:-
In 'manual' or 'Auto' setting, the vane will automatically change to Auto Air Swing.
• Economy Mode will stop if:-
– Economy mode button is pressed again.
– Stopped by ON/OFF switch.
– Timer–off activates.
– Powerful mode button is pressed.
– Auto or Manual air swing button is pressed.
1 hour
0 – 1 hour
TIME
TEMP.
SETTING
TEMPERATURE
Approx. 0.5
°
C increase
Approx. 0.5
°
C increase
Approx. 8 hours after
sleep shift operation
starts, stops automatically
Sleep Operation button is pressed.
Sleep shift Operation
starts.