– 15 –
MAC9512086C2
CS-C73KE
2
1
PROTECTOR
OVER LOAD
TERMINAL
OUTDOOR UNIT
YELLOW
RED
BLUE
COMPRESSOR TERMINAL
BRAND MARK
CAPACITOR
FAN MOTOR
CAPACITOR
R
B
B
Y
R
B
B
GRY
Y
COMPRESSOR
FUSE 3.15A
B
CN-FUSE(B)
CR4
3
1
W
W
R
R
R
R
(PIPE TEMP.)
SENSOR
(W)
AC
ZNR1
(TEST RUN)
Y
7
220-230V, 50Hz
BL
BL
CONTROLLER
ELECTRONIC
1
CN-C
(G)
ELECTRONIC CONTROLLER
4
3
1
2
CONTROL No.
REMOTE
A
B
BR
R
O
Y
P
Y/G
BL
W
W
R
BR
O
W
5
3
1
W
BR
FUSE(3.15A)
L
P
MOTOR
FAN
SSR
CAPACITOR
CN-FM(G)
ZNR2
RY-SHI
RY-H
RY-PWR
TRANSFORMER
PUMP DOWN SW
AUTO SW
CN-RCV (W)
(RECEIVER)
ELECTRONIC
CONTROLLER
WIRELESS
REMOTE
CONTROL
CN-DISP(W)
DISPLAY LAMP
POWER SUPPLY CORD
BR
B
Y/G
W
W
W
W
SENSOR
(INTAKE AIR TEMP.)
1
2
3
4
54321
CN-TH(Y)
CN-STM(G)
AIR
SWING
MOTOR
4
3
2
1
2
3
4
MAIN SW
CN-DISP(W)
INDOOR UNIT
TERMINAL
2
1
THERMAL
FUSE
(102
°
C)
THERMAL
FUSE
(113
°
C)
RY-M
CR3
CR1
CR2
1
3
B
9
7
6
5
8
1
2
3
5
6
W
W
W
W
W
J9890634
CS/CU-C73KE/C93KE/C123KE
C73KE07.DWG
Wiring Diagram
REMARKS:
B
: BLUE
BR
: BROWN
BL
: BLACK
W
: WHITE
R
: RED
O
: ORANGE
P
: PINK
Y/G
: YELLOW/
GREEN
MODEL
CONNECTION
YELLOW-BLUE
YELLOW-BROWN
BROWN-ORANGE
ORANGE-WHITE
WHITE-RED
Resistance of Indoor Fan Motor Windings
CS-C73KE
CWA92288
536.5
77.1
43.9
42.7
111.4
CS-C123KE
CWA92290
457.4
56.1
61.2
25.3
142.5
CS-C93KE
CWA92289
449.5
87.7
56.1
18.6
124.1
MODEL
CONNECTION
BLUE-YELLOW
YELLOW-RED
Resistance of Outdoor Fan Motor Windings
CU-C73KE
CWA95238
310.0
Ω
409.8
Ω
CU-C123KE
CWA95378
174.5
Ω
331.0
Ω
CU-C93KE
@
@
@
MODEL
CONNECTION
C-R
C-S
CU-C73KE
2RS110D5CA04
5.382
Ω
5.328
Ω
CU-C123KE
2KS224D5CA02
2.211
Ω
2.924
Ω
CU-C93KE
2PS146D5BA04
3.941
Ω
3.499
Ω
Resistance of Compressor Windings
CS-C73KE / CU-C73KE
CS-C93KE / CU-C93KE
CS-C123KE / CU-C123KE
Untitled-1
6/28/00, 4:11 PM