![Panasonic CS-C28GKF Service Manual Download Page 41](http://html.mh-extra.com/html/panasonic/cs-c28gkf/cs-c28gkf_service-manual_256682041.webp)
41
13 Servicing Mode
13.1. Auto OFF/ON Button
• The “Auto OFF/ON Button” (behind the front grille) is used to operate the air conditioner if remote control is misplaced or mal-
functioning.
• Forced cooling operation is possible by pressing the “Auto OFF/ON Button” for more than 5s where “beep” sound is heard then
release the button.
• User able to select remote control transmission code and toggle remote control signal receiving sound under various setting
mode.
• To enter various setting mode:
- Press the “Auto OFF/ON Button” continuously for 5s (beep sound is heard) and release.
- Within 20s, press the “Auto OFF/ON Button” continuously for 5s again (2 beep sound is heard) and release.
- Various setting mode has limit up to 20s. Then return to normal operation.
13.1.1. Toggle Remote Control Signal Receiving Sound
• Under various setting mode, press the “Auto OFF/ON Button” to toggle the remote control sound.
- Short “beep”: Turn ON remote control signal receiving sound.
- Long “beep”: Turn OFF remote control signal receiving sound.
• After “Auto OFF/ON Button” is pressed, the 20s counter for various setting mode is restarted.
13.1.2. Select Remote Control Transmission Code
• There are 4 type of remote control transmission code could be selected and stored in EEPROM of indoor unit. The indoor unit
will only operate when received signal with same transmission code from remote control. This could prevent signal interference
when there are 2 or more indoor unit installed nearby together.
• To change remote control transmission code, short or open jumpers at the remote control printed circuit board.
• Under various setting mode, after select the transmission code combination of remote control, press any button of remote control
to transmit a signal to indoor unit. The transmission code will be stored in EEPROM.
• After signal is received, the various setting mode is cancelled and return to normal operation.
Remote Control Printed Circuit Board
Transmission Code Combination
J-A
J-B
Remote Control No.
* Short
Open
A (default)
Open
Open
B
Short
Short
C
Open
Short
D
Summary of Contents for CS-C28GKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit ...
Page 10: ...10 5 2 Outdoor Unit ...
Page 11: ...11 6 Refrigeration Cycle Diagram ...
Page 12: ...12 7 Block Diagram ...
Page 13: ...13 8 Wiring Connection Diagram ...
Page 14: ...14 9 Electronic Circuit Diagram ...
Page 15: ...15 10 Printed Circuit Board 10 1 Main Printed Circuit Board ...
Page 16: ...16 ...
Page 17: ...17 10 2 Power Printed Circuit Board ...
Page 18: ...18 10 3 Indicator panel ...
Page 46: ...46 ...
Page 47: ...47 ...
Page 48: ...48 15 2 Indoor Fan Motor and Cross Flow Fan Removal Procedures ...
Page 49: ...49 ...
Page 50: ...50 16 Technical Data 16 1 Thermostat Characteristics 1 Characteristics of thermostat ...
Page 51: ...51 16 2 Operation Characteristics ...
Page 52: ...52 ...
Page 54: ...54 ...