12.7.2. Manual Control
• When the vertical airflow direction is set to Manual using the
remote control, the automatic airflow is released and the
airflow direction louver move up and down in the range
shown in the diagram.
• The louver can be adjusted by pressing the button to the
desired louver position.
• When stopped with remote control, the discharge vent is
reset, and stop at the closing position.
12.8. Horizontal Airflow Direction Control
12.8.1. Auto Control
• When the horizontal airflow direction is set to Auto using the
remote control, the vanes swings left and right as shown in
the diagram.
• When stopped with remote control, the discharge vane is
reset, and stop at the reset position.
• During Cooling operation or Soft Dry operation, indoor fan
motor may stop to rotate at certain periods. At that condition,
the vane will stop swinging and rest at 22° angle.
12.8.2. Manual Control
• When the horizontal airflow direction is set to Manual using
the remote control, the automatic airflow is released and the
airflow direction vane move left and right in the range shown
in the diagram.
The louver can be adjusted by pressing the button to the
desired vane position.
• When stopped with remote control, the vanes is reset, and
stopped at reset position.
12.9. Powerful Operation
• The Powerful operation is to achieve the setting temperature quickly.
• When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the present
setting temperature (Lower temperature limit: 16°C).
• This operation automatically will be running under SHi Fan Speed (Cooling).
• Vertical Airflow Direction:-
- In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.
- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
• Powerful operation stops when:-
- Powerful operation has operate for 15 minutes.
- Powerful mode button is pressed again.
- Stopped by OFF/ON operation button
- Timer OFF activates.
- Quiet mode button is pressed.
- Operation mode is changed.
Summary of Contents for CS-C28GKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit ...
Page 10: ...10 5 2 Outdoor Unit ...
Page 11: ...11 6 Refrigeration Cycle Diagram ...
Page 12: ...12 7 Block Diagram ...
Page 13: ...13 8 Wiring Connection Diagram ...
Page 14: ...14 9 Electronic Circuit Diagram ...
Page 15: ...15 10 Printed Circuit Board 10 1 Main Printed Circuit Board ...
Page 16: ...16 ...
Page 17: ...17 10 2 Power Printed Circuit Board ...
Page 18: ...18 10 3 Indicator panel ...
Page 46: ...46 ...
Page 47: ...47 ...
Page 48: ...48 15 2 Indoor Fan Motor and Cross Flow Fan Removal Procedures ...
Page 49: ...49 ...
Page 50: ...50 16 Technical Data 16 1 Thermostat Characteristics 1 Characteristics of thermostat ...
Page 51: ...51 16 2 Operation Characteristics ...
Page 52: ...52 ...
Page 54: ...54 ...