28
12.2. Soft Dry Operation
• Soft Dry operation can be set using remote control.
• Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room.
• This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control.
• When operation begins, Soft Dry will be switched “ON” for a maximum 10 minutes, then Soft Dry operation will be turned “OFF”
for a minimum 6 minutes. After that, the Soft Dry operation will be “ON” and “OFF” based on the setting temperature as shown in
below figure.
• However after 3 minutes of compressor off, during Soft Dry “OFF” (within 6 minutes Soft Dry restart control), the indoor unit will
start to operate at normal Cooling mode if the intake temperature is higher than Cooling “ON” point.
12.2.1.
Soft Dry Operation Time Diagram
Summary of Contents for CS-C18GKD
Page 11: ...11 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C18GK CS C24GK ...
Page 12: ...12 5 2 Outdoor Unit 5 2 1 CU C18GK 5 2 2 CU C24GK ...
Page 13: ...13 6 Refrigeration Cycle Diagram ...
Page 14: ...14 7 Block Diagram ...
Page 17: ...17 9 Electronic Circuit Diagram ...
Page 18: ...18 10 Printed Circuit Board 10 1 Indoor Unit TOP VIEW ...
Page 19: ...19 BOTTOM VIEW ...
Page 20: ...20 10 2 Indicator TOP VIEW BOTTOM VIEW ...
Page 50: ...50 ...
Page 51: ...51 ...
Page 52: ...52 15 2 Indoor Fan Motor and Cross Flow Fan Removal Procedures ...
Page 53: ...53 ...
Page 54: ...54 16 Technical Data 16 1 Thermostat Characteristics Cooling Soft Dry ...
Page 55: ...55 16 2 Operation Characteristics 16 2 1 CS C18GK CU C18GK ...
Page 56: ...56 ...
Page 57: ...57 16 2 2 CS C24GK CU C24GK ...
Page 58: ...58 ...