24
11.1.4.
CONNECT THE CABLE TO THE INDOOR UNIT
1. The inside and outside connecting cable can be
connected without removing the front grille.
2. Connecting cable between indoor unit and outdoor unit
shall be approved polychloroprene sheathed 3
×
2.5 mm
2
flexible cord, type designation 245 IEC 57 or heavier
cord.
• Ensure the colour of wires of outdoor unit and the
terminal Nos. are the same to the indoor’s respectively.
• Earth lead wire shall be longer than the other lead wires
as shown in the figure for the electrical safety in case of
the slipping out of the cord from the anchorage.
• Secure the cable onto the control board with the holder
(clamper).
11.2. Outdoor Unit
11.2.1.
INSTALL THE OUTDOOR UNIT
• After selecting the best location, start installation according
to Indoor/Outdoor Unit Installation Diagram.
1. Fix the unit on concrete or rigid frame firmly and horizon-
tally by bolt nut (ø10 mm).
2. When installing at roof, please consider strong wind and
earthquake. Please fasten the installation stand firmly
with bolt or nails.
Summary of Contents for CS-C18GKD
Page 11: ...11 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C18GK CS C24GK ...
Page 12: ...12 5 2 Outdoor Unit 5 2 1 CU C18GK 5 2 2 CU C24GK ...
Page 13: ...13 6 Refrigeration Cycle Diagram ...
Page 14: ...14 7 Block Diagram ...
Page 17: ...17 9 Electronic Circuit Diagram ...
Page 18: ...18 10 Printed Circuit Board 10 1 Indoor Unit TOP VIEW ...
Page 19: ...19 BOTTOM VIEW ...
Page 20: ...20 10 2 Indicator TOP VIEW BOTTOM VIEW ...
Page 50: ...50 ...
Page 51: ...51 ...
Page 52: ...52 15 2 Indoor Fan Motor and Cross Flow Fan Removal Procedures ...
Page 53: ...53 ...
Page 54: ...54 16 Technical Data 16 1 Thermostat Characteristics Cooling Soft Dry ...
Page 55: ...55 16 2 Operation Characteristics 16 2 1 CS C18GK CU C18GK ...
Page 56: ...56 ...
Page 57: ...57 16 2 2 CS C24GK CU C24GK ...
Page 58: ...58 ...