77
16. Troubleshooting
Guide
16.1 Refrigeration cycle system
In order to diagnose malfunctions, ensure the air conditioner is free
from electrical problems before inspecting the refrigeration cycle.
Such problems include insufficient insulation, problem with the
power source, malfunction of a compressor and a fan. The normal
outlet air temperature and pressure of the refrigeration cycle
depends on various conditions, the standard values for them are
shown in the table to the right.
Normal Pressure and Outlet Air Temperature (Standard)
Gas Pressure
Mpa
(kg/cm
2
G)
Outlet air
Temperature
(°C)
Cooling Mode
0.4 ~ 0.6 (4 ~ 6)
12 ~ 16
Condition: Indoor fan speed = High
Outdoor temperature = 35°C
Different in the intake
and outlet
air temperatures
Normal
Value of electric current
during operation
Dusty condenser
preventing heat radiation
Excessive amount
of refrigerant
Gas side
pressure
Inefficient compressor
Insufficient refrigerant
Clogged strainer or
capillary cube
•
Measuring the air
temperature different
•
Measuring electric current
during operation
•
Measuring gas side
pressure
More than 8
°
C
(15 minutes after an
operation is started)
Less than 8
°
C at the cooling mode
Higher than specified
Cooling
Mode
High
Low
Low
Lower than specified
Summary of Contents for CS-C12KKF-2
Page 10: ...10 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 11: ...11 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C12KKF 2 ...
Page 12: ...12 5 1 2 CS C18KKF 2 CS C24KKF 2 CS C28KKF 2 ...
Page 13: ...13 5 2 Outdoor Unit 5 2 1 CU C12KKF 2 CU C18KKF 2 ...
Page 14: ...14 5 2 2 CU C24KKF 2 CU C28KKF 2 ...
Page 16: ...16 7 Block Diagram 7 1 1 CS C12KKF 2 CU C12KKF 2 ...
Page 17: ...17 7 1 2 CS C18KKF 2 CU C18KKF 2 CS C24KKF 2 CU C24KKF 2 ...
Page 18: ...18 7 1 3 CS C28KKF 2 CU C28KKF 2 ...
Page 23: ...23 9 Electronic Circuit Diagram 9 1 CS C12KKF 2 CU C12KKF 2 ...
Page 24: ...24 9 2 CS C18KKF 2 CU C18KKF 2 ...
Page 25: ...25 9 3 CS C24KKF 2 CU C24KKF 2 ...
Page 26: ...26 9 4 CS C28KKF 2 CU C28KKF 2 ...
Page 27: ...27 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 28: ...28 10 1 2 Power Printed Circuit Board 10 1 2 1 CS C12KKF 2 ...
Page 29: ...29 10 1 2 2 CS C18KKF 2 CS C24KKF 2 CS C28KKF 2 ...
Page 80: ...80 Figure 3 Figure 4 Figure 5 17 1 1 3 To remove discharge grille Figure 6 ...
Page 82: ...82 Figure 10 Figure 11 ...
Page 84: ...84 17 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Page 86: ...86 Figure 21 Figure 22 Figure 23 ...
Page 88: ...88 17 3 1 3 To remove power electronic controller Figure 26 Figure 24 Figure 25 Figure 27 ...