Airflow direction (Horizontal, Vertical) Control
o
During any operation mode combines with Patrol operation, airflow direction follows respective operation
mode.
o
During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is
pressed, no signal is sent to air conditioner, and no change on LCD display.
o
During Patrol individual operation if e-ion stops, Airflow direction louver closed.
•
LED
display
(Applicable to all models except KKD models)
o
When Patrol operation is selected, Patrol LED illuminates.
o
During Patrol individual operation, only Patrol LED illuminates. When e-ion air purifying operation starts
based on dirtiness level, Power LED, Patrol LED and e-ion LED illuminates.
PATROL
LED
E-ION
TIMER
No Description
BLUE
ORANGE
RED
BLUE
ORANGE
1 When patrol function is not selected
OFF
OFF
OFF
-
-
2 During gas sensor error detection
control
OFF OFF Blinking OFF OFF
3 During E-ion abnormal discharge
error
OFF OFF OFF
Blinking
OFF
4 During E-ion breakdown error
OFF OFF OFF
Blinking
Blinking
5 During Test Mode
OFF
OFF
OFF
OFF
OFF
6 During stop
OFF
OFF
OFF
OFF
OFF
7 2 minutes gas sensor initial stabilization time (Level 0)
ON
OFF
OFF
OFF
OFF
a. Dirtiness level 0*
ON
OFF
OFF
OFF
OFF
b. Dirtiness level 1
OFF
ON
OFF
OFF
OFF
c. Dirtiness level 1*
OFF
ON
OFF
ON
OFF
8
During operation
During patrol
d. Dirtiness level 2
OFF
OFF
ON
ON
OFF
•
Remote Control Receiving Sound
o
Normal
Operation
Î
Patrol Mode
: Beep
o
Patrol
Mode
Î
Stop
: Long Beep
o
Patrol
Mode
Î
Normal Operation
: Beep
o
Stop
Î
Patrol
: Beep
•
Timer
Control
o
When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol
operation status.
o
When ON timer activates during any operation, no change and carry on current operation.
o
When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is
saved.
•
Power Failure Control
o
During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation
resumes immediately.
o
During combination operation, if power failure occurs, after power resumes combination operation resume
immediately.
Summary of Contents for CS-C12KKF-2
Page 10: ...10 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 11: ...11 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C12KKF 2 ...
Page 12: ...12 5 1 2 CS C18KKF 2 CS C24KKF 2 CS C28KKF 2 ...
Page 13: ...13 5 2 Outdoor Unit 5 2 1 CU C12KKF 2 CU C18KKF 2 ...
Page 14: ...14 5 2 2 CU C24KKF 2 CU C28KKF 2 ...
Page 16: ...16 7 Block Diagram 7 1 1 CS C12KKF 2 CU C12KKF 2 ...
Page 17: ...17 7 1 2 CS C18KKF 2 CU C18KKF 2 CS C24KKF 2 CU C24KKF 2 ...
Page 18: ...18 7 1 3 CS C28KKF 2 CU C28KKF 2 ...
Page 23: ...23 9 Electronic Circuit Diagram 9 1 CS C12KKF 2 CU C12KKF 2 ...
Page 24: ...24 9 2 CS C18KKF 2 CU C18KKF 2 ...
Page 25: ...25 9 3 CS C24KKF 2 CU C24KKF 2 ...
Page 26: ...26 9 4 CS C28KKF 2 CU C28KKF 2 ...
Page 27: ...27 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 28: ...28 10 1 2 Power Printed Circuit Board 10 1 2 1 CS C12KKF 2 ...
Page 29: ...29 10 1 2 2 CS C18KKF 2 CS C24KKF 2 CS C28KKF 2 ...
Page 80: ...80 Figure 3 Figure 4 Figure 5 17 1 1 3 To remove discharge grille Figure 6 ...
Page 82: ...82 Figure 10 Figure 11 ...
Page 84: ...84 17 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Page 86: ...86 Figure 21 Figure 22 Figure 23 ...
Page 88: ...88 17 3 1 3 To remove power electronic controller Figure 26 Figure 24 Figure 25 Figure 27 ...