During ECO Patrol operation, the internal setting temperature and fan speed are adjusted in order to provide
comfort and energy saving.
•
ECO Patrol Start condition.
Press ECO Patrol button to select ECO1 and ECO2.
•
ECO Patrol Stop condition.
Press ECO Patrol button again.
OFF Timer activates.
Press OFF/ON button to turn off the air conditioner.
Press AUTO OFF/ON button to turn off the air conditioner.
Press POWERFUL/QUIET button.
Press Mild Dry Cooling button.
•
ECO Patrol operation could ON when any of the following conditions is fulfilled:
During forced cooling or forced heating operation.
During e-ion or individual patrol operation.
•
Power Failure
ECO Patrol operation will be resuming after recovered from power failure.
•
Timer Operation
When unit is turn on by ON Timer and ECO Patrol operation is ON during previous operation before OFF,
ECO Patrol operation will not be ON automatically.
When unit is turn on by ON Timer and ECO Patrol operation is OFF during previous operation before
OFF, ECO Patrol operation will not be ON automatically.
•
Other Information
ECO Patrol, Powerful, Quiet and Mild Dry Cooling cannot be operated at the same time.
ECO Patrol sensor initialized time is 70 seconds from power supplied to ECO Patrol sensor, or 70
seconds from the operation start.
•
ECO 1 Operation
-1
o
C
+2
o
C
High
Low
None
Fan Speed
Set
Temperature
Activity Level
Set Speed
Set Speed
Med Fan
+1tap Up
•
ECO 2 Operation
-1
o
C
+2
o
C
High
Low
None
Fan Speed
Set
Temperature
Activity Level
Set Speed
+1tap Up*
Set Speed
Med Fan
+2tap Up
(Higher Airflow)
* For first 15 minutes only
Summary of Contents for CS-C12KKF-2
Page 10: ...10 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 11: ...11 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C12KKF 2 ...
Page 12: ...12 5 1 2 CS C18KKF 2 CS C24KKF 2 CS C28KKF 2 ...
Page 13: ...13 5 2 Outdoor Unit 5 2 1 CU C12KKF 2 CU C18KKF 2 ...
Page 14: ...14 5 2 2 CU C24KKF 2 CU C28KKF 2 ...
Page 16: ...16 7 Block Diagram 7 1 1 CS C12KKF 2 CU C12KKF 2 ...
Page 17: ...17 7 1 2 CS C18KKF 2 CU C18KKF 2 CS C24KKF 2 CU C24KKF 2 ...
Page 18: ...18 7 1 3 CS C28KKF 2 CU C28KKF 2 ...
Page 23: ...23 9 Electronic Circuit Diagram 9 1 CS C12KKF 2 CU C12KKF 2 ...
Page 24: ...24 9 2 CS C18KKF 2 CU C18KKF 2 ...
Page 25: ...25 9 3 CS C24KKF 2 CU C24KKF 2 ...
Page 26: ...26 9 4 CS C28KKF 2 CU C28KKF 2 ...
Page 27: ...27 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 28: ...28 10 1 2 Power Printed Circuit Board 10 1 2 1 CS C12KKF 2 ...
Page 29: ...29 10 1 2 2 CS C18KKF 2 CS C24KKF 2 CS C28KKF 2 ...
Page 80: ...80 Figure 3 Figure 4 Figure 5 17 1 1 3 To remove discharge grille Figure 6 ...
Page 82: ...82 Figure 10 Figure 11 ...
Page 84: ...84 17 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Page 86: ...86 Figure 21 Figure 22 Figure 23 ...
Page 88: ...88 17 3 1 3 To remove power electronic controller Figure 26 Figure 24 Figure 25 Figure 27 ...