32
12.10. Timer Control
12.10.1. ON Timer
• When the ON Timer is set by using the remote control, the unit will start to operate slightly before the set time, so that the room
will reach nearly to the set temperature by the set time.
• For Cooling and Soft Dry operation, the operation will start 15 minutes before the set time.
• For Automatic operation, the indoor fan will operate at SLo speed for 20 seconds, 15 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
12.10.2. OFF Timer
• When the OFF Timer is set by using the remote control, the unit will stop operate according to the desired setting.
Notes:
1. By pressing ON/OFF operation button, the ON Timer or OFF Timer setting will not be cancelled.
2. To cancel the previous timer setting, press CANCEL button.
3. To activate the previous timer setting, press SET button.
4. If main power supply is switched off, the Timer setting will be cancelled.
12.11. Random Auto Restart Control
• If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
resumed.
• It will start with previous operation mode and airflow direction.
• If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
• This Random Auto Restart Control is not available when Timer is set.
12.12. Remote Control Signal Receiving Sound
• Short beep sound will be heard when:-
- enable initial Patrol Operation.
• Long beep sound will be heard for others setting.
Summary of Contents for CS-C12HKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C12HK ...
Page 10: ...10 5 2 Outdoor Unit 5 2 1 CU C12HK ...
Page 11: ...11 6 Refrigeration Cycle Diagram ...
Page 12: ...12 7 Block Diagram ...
Page 14: ...14 9 Electronic Circuit Diagram ...
Page 15: ...15 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board TOP VIEW ...
Page 16: ...16 BOTTOM VIEW ...
Page 17: ...17 10 1 2 Power Printed Circuit Board TOP VIEW BOTTOM VIEW ...
Page 18: ...18 10 1 3 Indicator TOP VIEW BOTTOM VIEW ...
Page 46: ...46 ...
Page 47: ...47 16 1 3 To remove discharge grille 16 1 4 To remove control board ...
Page 48: ...48 16 1 5 To remove cross flow fan and indoor fan motor ...
Page 49: ...49 ...
Page 50: ...50 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 51: ...51 17 2 Operation Characteristics 17 2 1 CS C12HK CU C12HK ...
Page 52: ...52 ...
Page 54: ...54 ...