22
• How to pull the piping and drain hose out, in case of the
embedded piping.
• In case of left piping how to insert the connecting cable and
drain hose.
11.2.4.
Connect The Cable To The Indoor
Unit
1. The inside and outside connecting cable can be
connected without removing the front grille.
2. Connecting cable between indoor unit and outdoor unit
shall be approved polychloroprene sheathed 3 (C12HKF)
× 1.5mm
2
flexible cord, type designation 245 IEC 57 or
heavier cord.
• Ensure the colour of wires of outdoor unit and the
terminal Nos. are the same to the indoor’s respectively.
• Earth lead wire shall be longer than the other lead wires
as shown in the figure for the electrical safety in case of
the slipping out of the cord from the anchorage.
• Secure the cable onto the control board with the holder
(clamper).
11.3. Outdoor Unit
11.3.1.
Install The Outdoor Unit
• After selecting the best location, start installation according
to Indoor/Outdoor Unit Installation Diagram.
1. Fix the unit on concrete or rigid frame firmly and
horizontally by bolt nut (ø10 mm).
2. When installing at roof, please consider strong wind and
earthquake. Please fasten the installation stand firmly
with bolt or nails.
11.3.2.
Connecting The Piping
11.3.2.1. Connecting The Piping To Indoor
Unit
Please make flare after inserting flare nut (locate at joint portion
of tube assembly) onto the copper pipe. (In case of using long
piping)
Connect the piping
• Align the center of piping and sufficiently tighten the flare nut
with fingers.
• Further tighten the flare nut with torque wrench in specified
torque as stated in the table.
Model
A
B
C
D
C12HKF
570
105
18.5
320
Summary of Contents for CS-C12HKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C12HK ...
Page 10: ...10 5 2 Outdoor Unit 5 2 1 CU C12HK ...
Page 11: ...11 6 Refrigeration Cycle Diagram ...
Page 12: ...12 7 Block Diagram ...
Page 14: ...14 9 Electronic Circuit Diagram ...
Page 15: ...15 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board TOP VIEW ...
Page 16: ...16 BOTTOM VIEW ...
Page 17: ...17 10 1 2 Power Printed Circuit Board TOP VIEW BOTTOM VIEW ...
Page 18: ...18 10 1 3 Indicator TOP VIEW BOTTOM VIEW ...
Page 46: ...46 ...
Page 47: ...47 16 1 3 To remove discharge grille 16 1 4 To remove control board ...
Page 48: ...48 16 1 5 To remove cross flow fan and indoor fan motor ...
Page 49: ...49 ...
Page 50: ...50 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 51: ...51 17 2 Operation Characteristics 17 2 1 CS C12HK CU C12HK ...
Page 52: ...52 ...
Page 54: ...54 ...