![Panasonic CS-BE25TKE Service Manual Download Page 39](http://html.mh-extra.com/html/panasonic/cs-be25tke/cs-be25tke_service-manual_256614039.webp)
39
7 Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor
unit according to the diagram below.
8 Secure the power supply cord and connection cable onto the control board with the holder.
9 Close grille door by tighten with screw and close the front panel.
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the
electrical safety in case of the slipping out of the cord from the anchorage.
11.2.4.1 Wire Stripping and Connecting Requirement
3
2
1
t
i
n
u
r
o
o
d
t
u
o
e
h
t
n
o
s
l
a
n
i
m
r
e
T
Colour of wires (connection cable)
Terminals on the indoor unit
L
N
1
2
3
(Power supply cord)
Terminals on the isolating devices
(Disconnecting means)
(L) (N)
Recommended
length (mm)
a b
c
d e
f
g
55 35 35 50 40 35 60
WARNING
This equipment must
be properly earthed.
Recommended
length (mm)
Tape
Connection cable
Tape
Power supply cord
Terminal Board
Control
Board
Earth wire
longer than
others
AC wires
for safety
reason
Holder
Holder
Indoor & outdoor
connection cable
Isolating Devices
Outdoor unit
Power supply
cord
OR
OR
OR
Do not joint wires
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national wiring rules.
Conductor
over inserted
Wire stripping
No loose strand
when inserted
10 ± 1 mm
Conductor
fully inserted
PROHIBITED
Conductor not
fully inserted
PROHIBITED
ACCEPT
Indoor/outdoor
connection
terminal board
5 mm or more
(gap between wires)
WARNING
RISK OF FIRE
JOINING OF WIRES
MAY CAUSE
OVERHEATING AND
FIRE.