![Panasonic CS-BE25TKE Service Manual Download Page 109](http://html.mh-extra.com/html/panasonic/cs-be25tke/cs-be25tke_service-manual_256614109.webp)
109
18. Service
Data
Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced
heating mode.
18.1 Cool Mode Outdoor Air Temperature Characteristic
Condition
-
Indoor room temperature: 27°C Dry Bulb/19°C Wet Bulb
-
Unit setting: Standard piping length, forced cooling at 16°C, Hi fan
-
Compressor frequency: Rated for cooling operation
-
Piping length: 5m
-
Voltage:
220-230V
18.1.1 CS/CU-BE25TKE
Outdoor Air Temperature (°C)
Outdoor Air Temperature (°C)
Current (A)
Outdoor Air Temperature (°C)
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
0.80
0.85
0.90
0.95
1.00
1.05
1.10
1.15
12.00
13.00
14.00
15.00
16.00
17.00
18.00
19.00
Indoor Discahrge
Air Temperature (°C)
Low Pressure (MPa)
220V
230V
12
16
20
24
28
32
36
40
44
48
12
16
20
24
28
32
36
40
44
48
12
16
20
24
28
32
36
40
44
48