35
11.2 Indoor Unit
11.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from vibration.
Model
Dimension
1
2 3 4 5 6
BE20***,
KE25***, BE25***, DE25***,
KE35***, BE35***, DE35***
480 mm
90 mm
425 mm
425 mm
43 mm
95 mm
Model
Dimension
1
2 3 4 5 6
KE50***, BE50***, DE50***
490 mm
85 mm
439 mm
432 mm
43 mm
95 mm
The center of installation plate should be at more than
1
at right and left of the wall.
The distance from installation plate edge to ceiling should more than
2
.
From installation plate center to unit’s left side is
3
.
From installation plate center to unit’s right side is
4
.
B
: For left side piping, piping connection for liquid should be about
5
from this line.
: For left side piping, piping connection for gas should be about
6
from this line.
1 Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
o
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
a level gauge.
2 Drill the piping plate hole with ø70 mm hole-core drill.
o
Line according to the left and right side of the installation plate.
The meeting point of the extended line is the center of the hole.
Another method is by putting measuring tape at position as shown in the diagram above.
The hole center is obtained by measuring the distance namely 128 mm for left and right hole
respectively.
o
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
side.
3
4
B
A
C
Ceiling
Wall
Wall
Installation
plate
1
2
screw
More than
1
More than
1
Measuring Tape
Indoor unit
228 mm
128 mm
228 mm
128 mm
More than
2
For best strength of
INDOOR unit installation,
it is highly recommended
to locate “ ” at 5 position
as shown.
PIPE
HOLE
CENTER
PIPE
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
3
4
B
A
C
Ceiling
Wall
Wall
Installation
plate
1
2
screw
More than
1
More than
1
Measuring Tape
Indoor unit
241.5 mm
128 mm
241.5 mm
128 mm
More than
2
For best strength of
INDOOR unit installation,
it is highly recommended
to locate “ ” at 5 position
as shown.
PIPE
HOLE
CENTER
PIPE
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
128mm TO
PIPE HOLE
CENTER