108
17.2 Heat Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C
Voltage: 220-230V
17.2.1 CS-BE25TKE CU-BE25TKE
Indoor (°C)
Outdoor WB (°C)
DB
-15 -7 2 7 12
TC IP TC IP TC IP TC IP TC IP
24 1737 803 1928 865 2510 899 2912 781 3100 777
20 1740 759 2140 860 2610 920 3150 780 3225 777
16 1640 719 2185 823 2601 876 3329 779 3418 776
17.2.2 CS-BE35TKE CU-BE35TKE
Indoor (°C)
Outdoor WB (°C)
DB
-15 -7 2 7 12
TC IP TC IP TC IP TC IP TC IP
24 1823 928 2366 1057 3099 1104 3550 1042 3779 1036
20 1826 878 2600 1050 3190 1130 3840 1040 3931 1036
16 1721 831 2681 1005 3211 1075 4059 1039 4167 1034
17.2.3 CS-BE50TKE CU-BE50TKE
Indoor (°C)
Outdoor WB (°C)
DB
-15 -7 2 7 12
TC IP TC IP TC IP TC IP TC IP
24 3163 1927 4127 2113 5222 2129 4992 1592 5314 1584
20 3168 1824 4580 2100 5430 2180 5400 1590 5529 1584
16 2985 1726 4676 2010 5410 2075 5707 1588 5860 1581
TC - Total Cooling Capacity (W)
IP - Input Power (W)