Useful Information

Specifications

All specifications are subject to change without notice.

Power Line Communication interface

LAN interface

User interface

Standard

HD-PLC

Actual transmission 
speed

*1

*1 Results may vary depending on electrical conditions, network environment, and other 

factors. For information on how transmission speed is measured, access the Panasonic 
PLC Support Site at: 

http://panasonic.co.jp/pcc/products/en/plc/

UDP: Max. 70 Mbps

TCP

*2

: Max. 42 Mbps

*2 Using Linux FTP.

Maximum recommended 
no. of adaptors per 
network

*3

*3 Performance may be affected as more adaptors are added to the network.

16 (including the master)

Maximum recommended 
no. of devices connected to 
each adaptor

*4

*4 Connecting more network devices to an adaptor may increase network traffic and affect 

performance.

8

Standard

IEEE 802.3/IEEE 802.3u

Interface

10 Base-T
100 Base-TX
Auto MDI/MDI-X

Protocol

IPv4, IPv6, TCP, UDP

Access method

CSMA/CD

Indicators

PLC

 (blue, red)

LAN

 (green, orange)

MASTER

 (green)

Other

Mode Selector (

MASTER

 or 

TERMINAL

 switch)

SETUP

 button

FACTORY DEFAULT RESET

 button

Summary of Contents for BL-PA100KT

Page 1: ...k 8 Main unit 9 Installation Placing the adaptors 10 Connecting adaptors to network devices 11 Useful Information Testing a terminal s network speed 12 Understanding the indicators 13 Resetting an ada...

Page 2: ...hich means you can add additional adaptors whenever you need to add a network connection in another room of the house Simple network speed testing You can confirm the speed of each adaptor s HD PLC co...

Page 3: ...is product can be used Abbreviations This product is referred to as the adaptor in this document Trademarks Linux is the registered trademark of Linus Torvalds in the U S and other countries All other...

Page 4: ...ar the product and is easily accessible 6 Use only the included AC cord 7 The AC cord must remain connected at all times It is normal for this product to feel warm during use 8 To prevent the risk of...

Page 5: ...s on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point...

Page 6: ...electrical devices emit electrical noise If this noise is passed on to the electrical wiring in your home it may interfere with the performance speed and reliability of your adaptors For best results...

Page 7: ...e following situations If you are concerned that another adaptor may have been accidentally registered to your master for example the adaptor of someone who lives in the same apartment building as you...

Page 8: ...rk devices computers network printers network cameras etc When you re finished your network devices will be able to access the internet as well as each other Example of an integrated HD PLC network Ma...

Page 9: ...e adaptor is configured as the master For more information see page 13 5 SETUP Button Used to register the adaptor see page 15 or test the terminal s network speed see page 12 6 Mode Selector The posi...

Page 10: ...fore placing them where you plan to use them 1 Connect the AC cord of each adaptor to a wall outlet near where you plan to use it 2 Confirm that the PLC indicator of each adaptor lights in blue when y...

Page 11: ...network 1 Confirm that each adaptor s AC cord is connected to the adaptor and plugged into a wall outlet 2 Connect a LAN cable sold separately to each adaptor s LAN jack The LAN indicator of each adap...

Page 12: ...onnect the terminal to a different wall outlet and repeat the test Note At least one indicator Good network speed must be lit in order to use the terminal If you are not satisfied with the speed test...

Page 13: ...stration Try again Red lit The adaptor is not functioning properly and cannot communicate over the HD PLC network Contact an authorised Panasonic service centre Off The adaptor is not plugged in The a...

Page 14: ...e master You are registering an adaptor Note Resetting a terminal erases its registration to the master It must be registered to the master again in order to be used If the master is reset all termina...

Page 15: ...TORY DEFAULT RESET button on the terminal for about 3 seconds see page 14 Check the position of the adaptor s mode selector see page 9 and make sure that you reset the terminal adaptor not the master...

Page 16: ...ance issue is solved 1 Confirm that the AC cords of both the master and terminal adaptor are connected to the wall outlet If an adaptor s LAN indicator is not lit the adaptor is not receiving power 2...

Page 17: ...the device to a different wall outlet does not resolve the performance issue connect the device to a noise filtering power strip with an AC cord that is at least 3 m long Troubleshooting note 3 Elimin...

Page 18: ...DP Max 70 Mbps TCP 2 Max 42 Mbps 2 Using Linux FTP Maximum recommended no of adaptors per network 3 3 Performance may be affected as more adaptors are added to the network 16 including the master Maxi...

Page 19: ...requency band 4 28 MHz Modulation Wavelet OFDM 16 PAM 2 PAM Transmission PHY rate Max 190 Mbps 1 1 This is the theoretical maximum data transmission speed of the HD PLC standard Access method CSMA CA...

Page 20: ...s Reserved Copyright This material is copyrighted by Panasonic Communications Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the wr...

Reviews: