39
BL-C111A/BL-C131A
8.16. How to Replace a Flat Package IC
8.16.1. Preparation
• PbF (: Pb free) Solder
• Soldering Iron
Tip Temperature of 700
°
F ± 20
°
F (370
°
C ± 10
°
C)
Note:
We recommend a 30 to 40 Watt soldering iron. An
expert may be able to use a 60 to 80 Watt iron where some-
one with less experience could overheat and damage the
PCB foil.
• Flux
Recommended Flux: Specific Gravity
→
0.82.
Type
→
RMA (lower residue, non-cleaning type)
Note:
See
About Lead Free Solder (PbF: Pb free)
(P.3).
8.16.2. Procedure
1. Tack the flat pack IC to the PCB by temporarily soldering
two diagonally opposite pins in the correct positions on
the PCB.
Be certain each pin is located over the correct pad on the PCB.
2. Apply flux to all of the pins on the IC.
3. Being careful to not unsolder the tack points, slide the sol-
dering iron along the tips of the pins while feeding enough
solder to the tip so that it flows under the pins as they are
heated.
8.16.3. Removing Solder from Between
Pins
1. Add a small amount of solder to the bridged pins.
2. With a hot iron, use a sweeping motion along the flat part
of the pin to draw the solder from between the adjacent
pads.
Summary of Contents for BL C131A - Network Camera - Pan
Page 5: ...5 BL C111A BL C131A LENS BOARD I O BOARD ...
Page 17: ...17 BL C111A BL C131A 5 Location of Controls and Components ...
Page 18: ...18 BL C111A BL C131A 6 Installation Instructions ...
Page 19: ...19 BL C111A BL C131A ...
Page 21: ...21 BL C111A BL C131A 7 2 Connection ...
Page 25: ...25 BL C111A BL C131A 1 It does not turn on when LED mode is OFF on web setup menu ...
Page 26: ...26 BL C111A BL C131A 8 2 Indicator view Check ...
Page 27: ...27 BL C111A BL C131A 8 3 LAN Block Check 8 3 1 Green Light On ...
Page 28: ...28 BL C111A BL C131A 8 3 2 Orange Light Blinking 1 ...
Page 29: ...29 BL C111A BL C131A 8 3 3 Orange Light Blinking 2 ...
Page 30: ...30 BL C111A BL C131A 8 4 Camera Block Check ...
Page 31: ...31 BL C111A BL C131A 8 5 Power Supply Block Check ...
Page 33: ...33 BL C111A BL C131A 8 7 Pyroelectric Infrared Sensor Check ...
Page 34: ...34 BL C111A BL C131A 8 8 Sound Block Check ...
Page 35: ...35 BL C111A BL C131A 8 9 RF Block Check BL C131A ...
Page 64: ...64 BL C111A BL C131A M O1 O2 O3 P1 P2 P3 N1 N2 Power ON Start ...
Page 73: ...73 BL C111A BL C131A 16 2 Cabinet and Electrical Parts Location BL C131A ...
Page 74: ...74 BL C111A BL C131A 16 3 Accessories and Packing Materials BL C111A ...
Page 75: ...75 BL C111A BL C131A 16 4 Accessories and Packing Materials BL C131A ...