7
Mounting (AC adapter)
Precautions for installation
Be sure to use water-proof connecting cables.
Be sure to keep AC power switched off during installation and connection.
Before pressing the power switch on, make sure that all parts, including the housing and pan/tilt head, have been installed
and connected completely and free of errors.
Do not install the AC adapter at a cold place [below –4°F (–20°C)] or a hot place [over 113°F (45°C)] because extremely low
or high temperature will cause operation instability.
How to install
Fasten the pole mounting plate (supplied) and the belt (to be locally purchased) on the back of the AC adapter with the four bolts,
flat washers and spring washers (For M8: supplied).
Fasten the AC adapter to the pole using the pole mounting plate and the belt.
4-3/4”
(121 mm)
7-7/8”
(200 mm)
Pole
ø7-7/8” (200 mm)
11”
(280 mm)
5-3/4”
(146 mm)
3-
7/
8”
(98 mm)
2-
7/
16
”
(62 mm)
Pole mounting plate
Belt [width: 1-3/4” (45 mm) or less]
Bolts (4 pcs.)
Spring washers
Flat washers