87
2.
SERIAL CONT 1 to 5 (RJ‑45)
Use LAN cables to connect Panasonic remote cameras with serial (RS422) connections. Connect them with straight cables (category 5e or better
shielded cable).
Pin
number
Signal name
Description of signal
1
GND
Frame ground
2
TALLY
Tally output (open collector)
3
TXD –
Send data (–)
4
RXD –
Receive data (–)
5
RXD+
Receive data (+)
6
TXD+
Send data (+)
7
NC
Not used
8
NC
Not used
z
z
TALLY (pin number: 2) specifications
Voltage withstand: Max. 24 V DC
Current: Max. 50 mA
3.
IP CONT (RJ‑45)
Complies with 10BASE‑T/100BASE‑TX.
Allowing connection to a network device that supports the PoE standard (IEEE802.3af compliant).
4.
12V IN (DC 12 V)
Hirose Electric: HA16RA‑4P (77)
Accepts DC 12 V inputs from an external power supply.
Input voltage range: 10.8 V to 13.2 V
1
2
3
4
Pin No.
Function
1
GND
2
NC
3
NC
4
+12V
Control interface for external devices
(continued)