The black level can be adjusted when using a multiple number of
cameras including the unit. Ask your dealer to perform this adjustment.
(Use an oscilloscope or waveform monitor for the adjustment.)
Adjust the black level in accordance with the units and devices used.
When performing operations from a wireless
remote control
1.
Press the <IRIS MANU> button.
Set the iris to the manual mode.
2.
Press the <IRIS –> button.
The lens iris is stopped down.
3.
Press the <
4
> or <
5
> button to bring the cursor to
[Picture].
4.
Press the <
M
> button.
The [Picture 2/7] screen is displayed.
Picture 2/7
Chroma Level 0%
Chroma Phase 0
Master Pedestal 0
R Pedestal 0
G Pedestal 0
B Pedestal 0
Pedestal Offset Off
Return
5.
Press the <
4
> or <
5
> button to bring the cursor to
[Master Pedestal].
Picture 2/7
Chroma Level 0%
Chroma Phase 0
Master Pedestal 0
R Pedestal 0
G Pedestal 0
B Pedestal 0
Pedestal Offset Off
Return
6.
Press the <
M
> button to start the [Master Pedestal] value
blinking.
7.
Press the <
4
> or <
5
> button, change the [Master
Pedestal] value, and press the <
M
> button to enter the
selection.
Adjust the value so that it matches the black level.
The pedestal values can be adjusted finely using the [R Pedestal],
[G Pedestal] and [B Pedestal] settings. (→ page 48, page 104)
8.
Press and hold the <MENU> button for about 2 seconds.
The camera menu display is exited.
9.
If necessary, press the <IRIS AUTO> button to adjust the
iris automatically.
When performing operations from a controller
When using an AW-RP150 or AW-RP60
For details, refer to the operating instructions for the controller.