When using the WV‑Q105A (optional accessory)
It is recommended that you provide an inspection opening or other such space for access purposes in the area near where the equipment is installed in
order to facilitate installation and the wiring connections work.
Before mounting the mount bracket, check that the installation location is strong enough to withstand the total mass (approx. 3.1
k
g
(6.83 lb)) which will
be exerted once the camera is mounted.
Use the mount bracket where the space between the ceiling panel and the concrete ceiling is at least 100 mm (3-15/16 inches) high.
The bracket can be mounted where the thickness of the ceiling panel ranges from 5 mm (3/16 inches) to 40 mm (1-9/16 inches).
The drop-prevention wire (supplied with the WV-Q105A) must be used when mounting the direct ceiling mount bracket.
Height above ceiling panel:
At least 100 mm (3‑15/16 inches)
The anchor bolts must not protrude
beneath the ceiling panel.
Ceiling panel (plasterboard, etc. with a
thickness from 5 mm (3/16 inches) to
40 mm (1‑9/16 inches))
Anchor bolts
(Withdrawal strength: 294 N) (30 k
g
f) or more
φ60 mm (2-3/8 inches)
Concrete ceiling
1.
Refer to the Operating Instructions of the WV‑Q105A direct ceiling mount bracket, and attach the WV‑Q105A as well as the
drop‑prevention wire angle and drop‑prevention wire supplied with the WV‑Q105A to the anchor bolts.
Mounting the anchor bolts and direct ceiling mount bracket (
)
This job is facilitated if the direct ceiling mount bracket is loosely secured to the ceiling panel in one place, and the direct ceiling mount bracket and
anchor bolts are vertically aligned before the nuts are tightened up.
2.
First, remove the screws which were loosely fastened in step 1, and then align the camera mount bracket of the AW‑HE130
with the screw holes in the WV‑Q105A direct ceiling mount bracket and mount it in place.
• Use the mounting screws (the M4-L60 Phillips head screws with adhesive) supplied with the WV-Q105A as the mounting screws.
• Fasten the AC adaptor securely to the bottom or other surface of the reinforcing member made of channel steel where dust and other foreign matter
will not accumulate.
• Do not place the AC adaptor directly onto the ceiling panel or other such surface.
Drop‑prevention wire
angle (Supplied with
WV‑Q105A)
Anchor bolts
Space above the ceiling
Direct ceiling mount bracket WV‑Q105A (optional accessory)
Drop‑prevention wire
(Supplied with WV‑Q105A)
Plasterboard or other ceiling panel
Camera mount
bracket (Supplied
with AW‑HE130)
AW‑HE130
Mounting screw x 4
(Supplied with WV‑Q105A)
Channel steel
Secure the AC adaptor firmly to a
member made of channel steel.
(Ceiling
panel)
Inspection opening recommended
• The installation and wiring connection
work is facilitated if an inspection opening
is provided for access purposes.
(
): Fasten here using the nut.
3.
Install the AW‑HE130 camera by following the procedure starting with step 3 on page 8.
10
11
How to install and connect the unit (continued)