- 61 -
SETTING menu
[7] INTELLIGENT SET
ATW WIDTH [1 to 5]
The color temperature range (1 to 5) used for
tracking ATW is set here.
With D5600K OFF, the range is set centering
on 200K or so; with D5600K ON, it is set
centering on 5600K or so.
The general color temperature tracking
ranges are listed in the table below.
ATW
WIDTH
D5600K OFF
D5600K ON
1
Approx.
000K to 000K
Approx.
500K to 7000K
2
Approx.
2500K to 5000K
Approx.
000K to 8000K
3
Approx.
200K to 8000K
Approx.
2500K to 9500K
4
Approx.
1900K to 10000K
Approx.
200K to 10500K
5
Approx.
1600K to 11000K
Approx.
1600K to 11000K
IRIS ON LOCK
[LOCK, MANUAL, PANEL]
The IRIS operation status when the intelligent
functions are locked is selected here.
LOCK:
The iris is held in the lock start
status.
MANUAL: The iris is switched to manual
operation.
PANEL:
Control that is exercised from
the camera controller switches
the iris operation between
IRIS AUTO and MANUAL.
Setting of menu items