- 11 -
Use the multi-cable provided with the AK-HRP150G when supplying power from the
AK-HRP150G.
Use the cable provided with the AW-PH650 when supplying power from the AW-PH650.
When supplying power from the AW-PH00, use the AW-CA15H29G or the
AW-CAKH1G cable kit depending on the configuration of the control system.
Use the AW-CA15H29G when supplying power from the AW-PH05.
When supplying power separately, ensure that the specifications of the interface cable
given below are satisfied.
Interface cable specifications
Use a cable with a performance equivalent or superior to the specifications given below.
AK-HC1800N
(High-density D-sub 15-pin connector)
G/L GND
GND
DC power supply input
(+12 V)
Not used
Not used
G/L signal input
Not used
GND
DC GND
TX_N(EIA22)/
TXD(EIA22C) output
GND
TX_P(EIA22) output
RX_N(EIA22)/
RXD(EIA22C) input
GND
RX_P(EIA22) input
DC GND
DC power supply input
(+12 V)
G/L GND
G/L signal input
GND
RX_N(EIA22)/
RXD(EIA22C) input
RX_P(EIA22) input
TX_N(EIA22)/
TXD(EIA22C) output
TX_P(EIA22) output
Power input: +12 V ±10 %,
5 A or more
Cable length: 5 m or less
Connector: DHW10-15F200
made by Advanced Connectek Inc.
Cover:
DE-C8-J9-F5-1R
made by Japan Aviation Electronics Industry, Ltd.
Use a twisted-pair cable.
Major operating controls and their functions