![Panasonic AJ-LT95 Operating Instructions Manual Download Page 35](http://html.mh-extra.com/html/panasonic/aj-lt95/aj-lt95_operating-instructions-manual_272030035.webp)
270
The underlining indicates the factory setting.
202
ID SEL
0000
0001
OTHER
DVCPRO
This selects the ID information to be returned to the controller.
0: 20 25H (525i mode) is returned.
1: The DVCPRO’s own ID and F0 33H (525i mode) is returned.
<Note>
This operation is not performed in the 625i mode.
207
STOP BIT
0000
0001
1
2
This selects the RS-232C (EDL) stop bit.
0: 1 bit
1: 2 bits
[
205
BAUD RATE
0000
0001
0002
0003
0004
1200
2400
4800
9600
19200
This selects the RS-232C (EDL) transfer (baud) rate.
[
[
[
208
PARITY
0000
0001
0002
NON
ODD
EVEN
This selects the RS-232C (EDL) parity.
0: Parity bit is not used.
1: Parity bit is used with odd parity.
2: Parity bit is used with even parity.
[
FLOW CONTROL
0000
0001
NONE
RTSCTS
This selects the RS-232C (EDL) communication flow control.
0: No flow control using RTS/CTS.
1: Flow control using RTS/CTS.
[
271
EDL FORMAT
0000
0001
AGA850
CMX340
This selects the format in which the EDL is to be dumped.
0: Format which is common with Panasonic’s AG-A850.
1: Format which is common with the CMX340 editing system.
[
206
DATA LENGTH
0000
0001
7
8
This selects the RS-232C (EDL) data length.
0: 7 bits
1: 8 bits
[
Item
Setting
No.
Superimposed
display
No.
Superimposed
display
Description of setting
V
T
R
1
V
T
R
2
35
Setup menus
INTERFACE menu
Summary of Contents for AJ-LT95
Page 93: ......
Page 187: ......