![Panasonic AJ-LT95 Operating Instructions Manual Download Page 34](http://html.mh-extra.com/html/panasonic/aj-lt95/aj-lt95_operating-instructions-manual_272030034.webp)
OPERATION menu
The underlining indicates the factory setting.
170
HUMID OPE
0000
0001
OFF
ON
This selects whether the unit is to continue operating when
condensation has formed.
0: The unit does not operate.
1: It operates even when condensation has formed but no
guarantees are made for its operation.
<Note>
Since tape damage or other problems may occur when “1: ON”
has been selected, the “0: OFF” setting should normally be used.
171
ALL STOP SEL
0000
0001
STOP
STILL
This selects the unit’s mode to be established when the ALL
STOP button has been pressed.
0: The unit is set to the STOP mode.
1: The unit is set to the still-picture (SHTL + 0.0, JOG STILL)
mode.
[
[
110
MEMORY STOP
0000
0001
OFF
ON
This selects the processing to be conducted when the counter
displays zeros in the CTL mode or during FF or REW.
0: The VTR is not shut down.
1: The VTR is automatically shut down.
<Note>
O
For the stop mode, either the stop or still-picture (SHTL + 0.0,
JOG STILL) mode is set depending on the setup menu item
No.315 (AFTER CUE-UP) setting.
O
When both the AUTO REW function and MEMORY function
have been selected, the AUTO REW function takes priority.
[
[
Item
Setting
No.
Superimposed
display
No.
Superimposed
display
Description of setting
V
T
R
1
V
T
R
2
172
VTR1 IN SEL
0000
0001
V1 IN
V2 IN
This selects the VIDEO/AUDIO input of VTR1 when the analog
signal input has been selected.
0: VTR1 IN serves as the VTR1 input.
1: VIDEO IN and AUDIO IN of VTR2 serve as the VTR1 input.
<Notes>
O
The unit will not operate when SDI signal input has been
selected.
O
This operation is not performed in the 625i mode.
[
173
BATTERY SEL
0000
0001
0002
0003
0004
0005
0006
0007
0008
10.8V
11.0V
11.2V
11.4V
11.6V
11.8V
12.0V
12.5V
13.0V
This selects the voltage threshold for warning when the DC supply
voltage has dropped.
(The unit’s power is automatically turned off when it drops to 10.6
V.)
0: When it has dropped to 10.8 V
1: When it has dropped to 11.0 V
2: When it has dropped to 11.2 V
3: When it has dropped to 11.4 V
4: When it has dropped to 11.6 V
5: When it has dropped to 11.8 V
6: When it has dropped to 12.0 V
7: When it has dropped to 12.5 V
8: When it has dropped to 13.0 V
[
174
SDI OUT
0000
0001
VTR1
VTR2
This selects the SDI output.
0: The VTR1’s signals are output.
1: The VTR2’s signals are output.
[
34
Setup menus
Summary of Contents for AJ-LT95
Page 93: ......
Page 187: ......
Page 188: ...Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 ...