- 12 -
1) Device overview
5. Common specifications
*1
To be set from touch screen.
*2
Customers shall prepare the cable to be connected to D-Sub37 connector.
*3
Customers shall prepare the power cable (AC supply cable) with the diameter appropriate for the maximum
input current.
*4
Excluding protruding parts of connectors and cables
*5
Excluding connectors and cables
Input power supply voltage
Single phase AC 200 to 240V
Input power supply frequency
50 to 60Hz
Number of radiation program patterns
32 patterns
*1
Display / setting / operation
Display / setting / operation from touch screen
External control
Type
Parallel I/O (D-Sub37
*2
)
External input
LED lighting / program selection / individual LED block lighting
Local-remote switching / external emergency stop
External output
Equipment power ON / LED radiation ready / during radiation / warning / error
Main unit emergency stop
Dimming control
*1
50% to 100% (in increments of 1%)
LED temperature feedback
Function to detect LED heard temperature to stabilize UV output
Operating ambient temperature
0 to +35ºC
Operating ambient humidity
30 to 85%RH (at 25
°
C, no dewing or freezing)
Storage ambient temperature
-10 to +60ºC
Storage ambient humidity
30 to 85%RH (at 25
°
C, no dewing or freezing)
Configuration
Control unit equipped with PLC, power supply for LED lighting
Separate type radiation unit equipped with UV-LED
AC inlet
Terminal block (screw diameter of terminal block: ø4)
*3
Cooling method
Control unit
Fan-less natural air-cooling
Power unit
Forced air-cooling with fan
Outer surface finish
Control unit
Matte black coat
Power unit
Size
*4
Control unit
W
×
H
×
D=280mm
×
223mm
×
560mm
Power unit
W
×
H
×
D=280mm
×
301mm
×
326mm
Weight
*5
of control unit
Approx. 10kg
Outline drawing
See P.16 to 17
Space for installation
See P.20
Included items
Control unit
Power keys, D-Sub37 connector
Power unit
Signal cable, AC connection cable, LED head connection cable
Applicable Standards
-