background image

 

PS-A (ADP5)

 

 

PS-A PRESSURE 

SENSOR

 

(built-in amplification and 
temperature compensating circuit)

 

Pressure sensor with 
built-in amplification 
and temperature 
compensation circuit

 

FEATURES

 

1. Contains built-in amplification and 
temperature compensation circuit. 
Circuit design and adjustment of 
characteristics are not required by 
users.

2. High-level precision and high 
reliability realized. (Overall accuracy is 
±1.25% FS.)

3. Compact pressure sensor unit that 
saves space.

 

Same size and footprint (7.0 mm (W) x 7.2 
mm (D)) as previous PS pressure sensor.

 

Example of pressure characteristics

 

(ADP5140)
Drive voltage: 5V DC rated voltage; 
ambient temperature: 25°C 

77°F

 

TYPICAL APPLICATIONS

 

• Gas equipment: Microprocessor gas 

meter, gas leakage detector

• Industrial equipment: Absorption 

device, etc.

5

1

2

4

3

0

0

50

100

Pressure (gauge pressure), (kPa {kgf/cm

2

})

Output voltage, mV

 

ORDERING INFORMATION

Part No.

ADP5: 
PS-A pressure sensor

Terminal profile

1: 

2: 

DIP terminal

SMD terminal

Rated pressure

0: 
1: 
2: 
3: 
4: 
5: 
6: 
7: 

±

100 kPa

–100 kPa

25 kPa
50 kPa

100 kPa
200 kPa
500 kPa

1,000 kPa

Pressure inlet hole length

0: 3 mm 

.118 inch

1: 5 mm 

.197 inch

Ex. ADP

5

 

PRODUCT TYPES

 

Pressure inlet

hole length

Part No.

Part No.

Packing quantity

3mm

5mm

3mm

5mm

Inner

Outer

Pressure

Terminal

DIP 
terminal

DIP 
terminal

SMD 
terminal

SMD 
terminal

±100kPa

ADP5100

ADP5101

ADP5200

ADP5201

100 

pcs.

1,000 

pcs.

–100kPa

ADP5110

ADP5111

ADP5210

ADP5211

25kPa

ADP5120

ADP5121

ADP5220

ADP5221

50kPa

ADP5130

ADP5131

ADP5230

ADP5231

100kPa

ADP5140

ADP5141

ADP5240

ADP5241

200kPa

ADP5150

ADP5151

ADP5250

ADP5251

500kPa

ADP5160

ADP5161

ADP5260

ADP5261

1,000kPa

ADP5170

ADP5171

ADP5270

ADP5271

 

NEW

Summary of Contents for ADP5100

Page 1: ...leakage detector Industrial equipment Absorption device etc 5 1 2 4 3 0 0 50 100 Pressure gauge pressure kPa kgf cm2 Output voltage mV ORDERING INFORMATION Part No ADP5 PS A pressure sensor Terminal profile 1 2 DIP terminal SMD terminal Rated pressure 0 1 2 3 4 5 6 7 100 kPa 100 kPa 25 kPa 50 kPa 100 kPa 200 kPa 500 kPa 1 000 kPa Pressure inlet hole length 0 3 mm 118 inch 1 5 mm 197 inch Ex ADP 5 ...

Page 2: ... 25 C 77 F Applied pressure 0 to 1 000kPa 1 2 Overall accuracy Offset voltage ADP5170 Drive voltage 5V DC temperature 0 to 50 C 32 to 122 F Applied pressure 0kPa 1 3 Overall accuracy Rated output voltage ADP5170 Drive voltage 5V DC temperature 0 to 50 C 32 to 122 F Applied pressure 1 000kPa Pressure kPa Output voltage V 0 0 1 2 3 4 5 500 1000 Temperature C F Accuracy FS 0 32 1 25 1 00 0 75 0 50 0 ...

Page 3: ...imes 2 hrs each Passed Dropping resistance Dropping height 75 cm 29 528 inch Times 2 times Passed Terminal strength Pulling strength 9 8 N 1 kgf 10 sec Bending strength 4 9 N 0 5 kgf left and right 90 1 time Passed Soldering Resistance Soldered in DIP soldering bath Temperature 230 C 446 F Time 5 sec Passed Temperature DIP Temperature 260 C 500 F Time 10 sec Passed DIMENSIONS 1 DIP terminal Pressu...

Page 4: ... Ground 2 5 098 2 5 098 6 0 9 dia 6 35 dia 7 5 295 Vcc 5V DC Vout C 0 1µF GND mm inch General tolerance 0 3 012 3 SMD terminal Pressure inlet hole 3mm ADP52 0 NC GND NC Vcc NC Vout Vcc NC Vout 10 0 0 3 394 012 0 5 020 JAPAN 2 5 0 25 098 010 098 010 2 5 0 25 0 25 0 1 010 004 NC GND NC T Y R W Q E Atmospheric pressure inlet hole Pressure inlet hole 2 2 dia 087 dia R0 2 R 008 3 0 dia 4 R0 7 4 R 028 0...

Page 5: ...solder printing method as the method for cream solder printing Please refer to the recommended PCB specification diagram for the PCB foot pattern Self alignment may not always work as expected therefore please carefully adjust the position of the terminals and pattern The profile temperature is the value measured on the PCB near the terminals When doing reflow soldering on the back of the PC board...

Page 6: ...ake steps to prevent the pressure sensor chip from being exposed to light 8 Avoid using the pressure sensor chip where it will be susceptible to ultrasonic or other high frequency vibration 6 Quality check under actual loading conditions To assure reliability check the sensor under actual loading conditions Avoid any situation that may adversely affect its performance 7 Other handling precautions ...

Reviews: