No. SX-DSV02308 - 33 -
R1.0
Motor Business Unit, Appliances Company, Panasonic Corporation
8-3 Precautions for Wiring
(1) Wiring to power connector and terminal block
100/200 V Sizes A–D:
Short cable
Detach it when using an
external regenerative resistor
(Sizes C,D).
ALM
MC
Main power
supply
Motor
Connection
XA
XB
X4
OFF
4
L
ON
MCCB
Red
12–24 VDC
• When used in single phase
power supply, make sure to
connect it between terminals
L1, L3.
Thermal protector with built-in
external regenerative resistor
L1
L2
L3
L1C
L2C
Noise F
ilter
External regenerative
resistor
White
Black
Green
ALM+
ALM-
3
ALM
U
V
W
B1
B3
B2
MC
Power supply (3-phase)
Power supply (Single-phase)
Control
power supply