No. SX-DSV03335 - 76-
R2.0
Industrial Device Solution Business Unit, Panasonic Corporation
9. Compliance with global standards
9-1 Conforming standards
European EU
directive
EMC directive
EN55011
EN61000-6-2
EN61000-6-4
EN61800-3
Low voltage directive
EN61800-5-1
EN50178
Machinery directive
Functional Safety
ISO13849-1
EN61508
EN62061
EN61800-5-2
IEC61326-3-1
IEC60204-1
UL standard
UL61800-5-1 (File No. E164620)
CSA standard
C22. 2 No. 274
KC
KN11
KN61000-4-2,3,4,5,6,8,11
IEC : International Electrotechnical Commission
EN
: Europaischen Norman
EMC : Electromagnetic Compatibility
UL
: Under writers Laboratoris
CSA : Canadian Standards Association
KC
: Radio Waves Act(South Korea)
The parameter of functional safety
With diagnosis of “EDM output”
Without diagnosis of “EDM output”
Safety Integrity Level
EN61508(SIL3)
EN62061(SILCL3)
EN61508(SIL2)
EN62061(SILCL2)
Performance Level
ISO13849-1 PL e (Cat.3)
ISO13849-1 PL d (Cat.3)
Safety Function
EN61800-5-2 (SIL 3, STO)
EN61800-5-2 (SIL 2, STO)
Probability of dangerous
failure
<For size A,B,C,D,E,F>
PFH = 1.34 ×10
-8
(%SIL3=13.4%)
<For size G and H>
PFH = 1.78 ×10
-8
(%SIL3=17.8%)
<For size A,B,C,D,E,F>
PFH = 1.40 ×10
-8
(%SIL2=1.40%)
<For size G and H>
PFH = 1.85 ×10
-8
(%SIL2=1.85%)
Mean time to dangerous
failure
MTTFd : High (100 years)
MTTFd : High (100 years)
Average diagnostic coverage
DC : Medium
DC : Low
Mission time
15 years
15 years
9-2 European EU directive
Our products, in order to make it easy for the embedded equipments and devices to be compliant with EU
directive, provide the compliance with the standards associated with low voltage directive.
9-2-1 Compliance with EMC directive
This product is not intended to be used in low-voltage networks supplied to home facilities.
When used in such a network, high frequency interference is assumed.
To conform to EMC directive, please use noise filter , surge absorber and ferrite core. Regarding compliance
with
For compliance with EMC directives in machinery or equipment, confirmation with the final machine
or equipment incorporating the servo driver and servomotor is necessary.