Fire alarm systems 

External Fire Brigade 

Panel 1826 

 

Control and indicating panel for the fire brigade personnel 

 

Built-in printer (option) 

Ext. Fire Brigade Panel 

This unit is intended to be used by the fire 
brigade personnel, i.e. for pre-warning, co-
incidence, fire and heavy smoke / heat alarm 
presentation.  Point or zone alarm 
presentation and fire alarm reset are as in the 
c.i.e. it is connected to.  You can scroll 
amongst two or more alarms in the system.  
All or selected alarms will be presented in 
the unit's display (LCD, 2x40 characters 
with back-light).  An alarm text will be 
presented together with each alarm, if 
programmed in the c.i.e.  Furthermore, > 
617 texts for selected alarms can be stored in 
the unit and will in such a case be shown, 
instead of the texts sent from the c.i.e. for 
these alarms.  A built-in buzzer will sound 
like in the c.i.e.  Any fault in the system will 
be presented as "General fault in system" 
and the buzzer will sound.  The unit is 
power supplied via the c.i.e. or ext. power 
supply. 

LEDs, push buttons etc. 

The unit has the following LEDs: 

 

Fire

 and 

Alarms queued

, indicating 

pre-warning, co-incidence, fire and 
heavy smoke / heat alarm. 

 

Operation

, indicating that the unit is 

connected to a c.i.e. and power 
supplied, i.e. it is in operation. 

 

Extinguishing

, indicating activated 

output for Extinguishing equipment. 

 

Ventilation

, indicating activated output 

for Ventilation equipment. 

 

Fire brigade tx

, indicating activated 

output for Fire brigade tx (routing 
equipment). 

The unit has the following push buttons: 

 

Alarms queued

, used to scroll amongst 

the alarms. 

 

Silence buzzer

, used to silence the 

buzzer (it will re-sound for a new 
alarm. 

 

Silence alarm devices

, used to silence 

the alarm devices (they will re-sound 
for a new alarm. 

 

Reset

, used to reset the fire alarms. 

 

, used for paper feed, when the unit is 

provided with a printer 1835 (option). 

The designation texts on the front are in 
1826SE in Swedish but a neutral front for 
other languages is available (1826CC). 

Ext. FBP 1826 & Printer 1835 

The ext. FBP

 

1826

 consists of a grey metal 

cabinet with a door.  A key is required to 
open the door, which has a Plexiglas in front 
of the FBP front, see photo. It has cable 
inlets on the top, bottom and back sides and 
is intended to be wall mounted.  Two 
compression glands are attached.   

 

Printer 1835

 can be mounted in the ext. 

FBP 1826.  It will print all the alarms, 
including the alarm texts. 

SW mode and address setting 

The display and the push buttons are used to 
set the 

SW mode 

and 

address

, see the 

opposite side of this page. 

Product application 

The 1826 unit is intended for indoor use and 
in dry premises.  SW mode 

1826/28 – 1587 

2nd Cab

 is intended to be used in the 

systems EBL512 and EBL128 and SW 
mode 

1826/28 – 1582 2nd Cab

 in the 

systems EBL500 / 512 / 1000 / 2000. 