March 2006
910-257C
MG2 Series
Page 4-9
4.5.3 Resolution
Resolution allows the user to change the number of decimal points
displayed in the thickness display.
The user can select between Standard (0.001" or 0.01 mm) and Low
(0.01" or 0.1 mm).
To changing resolution:
Step 1:
Press [2ndF][
](Setup) to display the setup tabs.
Step 2:
Use the [
,
] keys to highlight the MEAS tab.
Step 3:
Use the [
] key to highlight Resolution and the [
,
]
keys to select Standard or Low.
Step 4:
Press [MEAS] to return to the Measure Mode.
4.5.4 Min/Max
Min/Max allows the user to put the gage in Min or Max scanning
mode. This feature allows the user to scan over an area and quickly
determine the minimum or maximum thickness.
Min Mode displays live thickness values and recalls the minimum
thickness when a LOS (loss of signal) occurs. Live thickness values
are displayed in filled-in form, and recalled min values are displayed
in outlined form. The minimum values are retained in a temporary
memory until new minimum thickness values replace them or until the
[Meas] key is pressed to reset the minimum. When Min Mode is
selected, the MG2 automatically changes to 20 Hz fast update mode.
Max Mode displays live thickness value and recalls the maximum
thickness when a LOS (loss of signal) occurs. Live thickness values
Summary of Contents for MG2
Page 1: ...USER S MANUAL MG2 MG2 XT MG2 DL Ultrasonic Thickness Gages Part No 910 257C...
Page 14: ...910 257C March 2006 Page 1 6 MG2 Series...
Page 32: ...910 257C March 2006 Page 3 14 MG2 Series...
Page 80: ...910 257C March 2006 Page 4 48 MG2 Series...
Page 107: ...March 2006 910 257C MG2 Series Page 5 27...
Page 108: ...910 257C March 2006 Page 5 28 MG2 Series...
Page 114: ...910 257C March 2006 Page 6 6 MG2 Series...