background image

6

Identify Connected Equipment 

Use this diagram to write in what pieces of equipment are plugged into each outlet for an easy reference.  

PLEASE NOTE 

that the outlets start at No. 8 

on the left. The outlet indicator lights on the front panel are numbered 1 through 8 left to right. 

OUTLET

OUTLET

OUTLET

OUTLET

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

8

7

6

5

4

3

2

1

Additional Notes:

__________________________________________
__________________________________________
__________________________________________
__________________________________________
__________________________________________
__________________________________________
__________________________________________
__________________________________________
__________________________________________
__________________________________________

1       2

 

LAN        TEL

1                 2                 3                4                5                 6                 7                8

UNSAFE VOLTAGE

    BREAKER

      WIRING FAULT

  TEMPERATURE

15 A

BRIGHTNESS

OUTLET STATUS

REBOOT 1                       REBOOT 2

M4315-PRO

B LT

Blue

 

ENABLED

   VOLTS

ALWAYS ON

CATV/SAT

FRONT 

PANEL OUTLET

OUTLET

OUTLET

OUTLET

OUTLET

MAC ADDRESS    __ __-__ __-__ __-__ __ -__ __-__ __

CHALLENGE KEY __ __ __ __-__ __ __ __-__ __ __ __

Name / Location of Installation

___________________________________________
___________________________________________
___________________________________________

Phone Number(s)

___________________________________________
___________________________________________

Summary of Contents for M4315-PRO

Page 1: ...B LT Blue ENABLED VOLTS Power Management with Control System Interactive Functionality 15 Amp Capacity M4315 PRO 8 Individually Controllable Rear Panel Outlets Fully Programmable TCP IP BlueBOLT Insta...

Page 2: ...BRIGHTNESS OUTLET STATUS REBOOT 1 REBOOT 2 M4315 PRO B LT Blue ENABLED VOLTS RS232 Table of Contents Feature Descriptions pg 1 Important Safety Instructions Front Panel Features Overview pg 2 Preset P...

Page 3: ...time This can cause speaker thumps which are not only annoy ing but can also damage the speakers and or trip product circuit breakers The M4315 PRO is designed to eliminate these transients by providi...

Page 4: ...connection Front Panel Features Overview PULL OUT CARD Quick reference for default profile and device type list Located under the reboot buttons REBOOT 1 2 Press either button for 2 seconds to initiat...

Page 5: ...d off BREAKER or holding both REBOOT buttons A V EXTENDED DELAYS OUTLET SEQUENCING profile P3 by outlet s Start up 1 10 sec 2 10 sec 3 10 sec 4 10 sec 5 10 sec 6 10 sec 7 20 sec 8 Shut down 8 20 sec 7...

Page 6: ...______________________ BANK 4 High Current Outlets Outlets 7 8 60dB 5 kHz 450 kHz 46dB 450 kHz 1 MHz 4 CATV SAT 1 2 Universal voltage 75V clamping HD 1080i p ready 0 5 dB 0 Hz 2 2 GHz 5 LAN Cat 5e 10...

Page 7: ...e room Step 1 Connect the power supply for the modem router into the M4315 PRO Step 2 Connect the coaxial line or telephone DSL line from the wall to M4315 PRO signal line pass through protection circ...

Page 8: ...________________________________________ __________________________________________ __________________________________________ __________________________________________ ______________________________...

Page 9: ...s list before proceeding The BlueBOLT CV1 should already be factory installed in this Panamax M4315 PRO component To switch from BlueBOLT functionality to RS 232 connectivity follow these steps 1 Unpl...

Page 10: ...4 ALL ON Turns on all outlets Turn on is immediate with no delay 3 4 1 Command ALL_ON CR 3 4 2 Action All outlet relays turn ON Terminates any running turn on or turn off sequence Overrides the DC tri...

Page 11: ...FOR 6 20 11 DELAY FOR 7 21 6 DELAY FOR 8 26 1 3 7 SET REBOOT DELAY Assign the delay between the last outlet turning off and the beginning of the turn on se quence in a reboot cycle 3 7 1 Command SET_R...

Page 12: ...e PROFILE n SELECTED CR 4 QUERIES 4 0 IDENTIFY Request that the unit identify itself 4 0 1 Query ID CR 4 0 2 Response PANAMAX CR MAX 4315 PRO CR FIRMWARE revision CR 4 1 FAULT STATUS Request the on of...

Page 13: ...REAKER status CR 5 7 3 Condition When a wire fault is detected a message will be sent to indicate the status of the indicator 5 7 4 Message WIRE FAULT status CR 5 7 5 Condition When the temperature ex...

Page 14: ...number and a description of the problem Contacting Customer Service 2010 Panamax LLC 1690 Corporate Circle Petaluma CA 94954 www panamax com 707 283 5900 Fax 707 283 5901 INS00859 REV D 5 11 10 12 M43...