10
REBOOT1 DELAY
= 30
REBOOT2 DELAY
= 30
FEEDBACK = ON
LINEFEED = ON
PROFILE = 2
3.12.4
Action:
P3 configuration below:
TRIGGER FOR 1
= BUTTON_1, GREEN_BUTTON
TRIGGER FOR 2
= GREEN_BUTTON
TRIGGER FOR 3
= BUTTON_2, GREEN_BUTTON
TRIGGER FOR 4
= GREEN_BUTTON
TRIGGER FOR 5
= DC_TRIGGER , GREEN_BUTTON
TRIGGER FOR 6
= BUTTON_1, GREEN_BUTTON
TRIGGER FOR 7
= DC_TRIGGER, GREEN_BUTTON
TRIGGER FOR 8
= DC_TRIGGER, GREEN_BUTTON
DELAY FOR 1
= 1,90
DELAY FOR 2
= 10,80
DELAY FOR 3
= 20,70
DELAY FOR 4
= 30,60
DELAY FOR 5
= 40,50
DELAY FOR 6
= 50,40
DELAY FOR 7
= 60,20
DELAY FOR 8
= 80,1
REBOOT1 DELAY
= 45
REBOOT2 DELAY
= 45
FEEDBACK = ON
LINEFEED = ON
PROFILE = 3
3.12.5
Action:
P4 configuration below:
TRIGGER FOR 1
= BUTTON_1
TRIGGER FOR 2
= BUTTON_2
TRIGGER FOR 3
= BUTTON_2, GREEN_BUTTON
TRIGGER FOR 4
= GREEN_BUTTON
TRIGGER FOR 5
= GREEN_BUTTON
TRIGGER FOR 6
= BUTTON_1, GREEN_BUTTON
TRIGGER FOR 7
= DC_TRIGGER
TRIGGER FOR 8
= DC_TRIGGER
DELAY FOR 1
= 1, O
DELAY FOR 2
= 16, O
DELAY FOR 3
= 31, 36
DELAY FOR 4
= 36, 31
DELAY FOR 5
= 41, 26
DELAY FOR 6
= 46, 21
DELAY FOR 7
= 51, 11
DELAY FOR 8
= 61, 1
REBOOT1 DELAY
= 30
REBOOT2 DELAY
= 30
FEEDBACK = ON
LINEFEED = ON
PROFILE = 4
3.12.3 Response: $PROFILE n SELECTED<CR>
4. QUERIES
4.0 IDENTIFY
Request that the unit identify itself.
4.0.1
Query:
?ID<CR>
4.0.2
Response:
$PANAMAX<CR>
$MAX 4315-PRO<CR>
$FIRMWARE: revision<CR>
4.1 FAULT STATUS
Request the on/off status of the outlets and output trigger.
4.1.1
Query:
?FAULTSTAT<CR>
4.1.2
Response:
$PWR = status<CR>
$BREAKER = status<CR>
$WIRE FAULT = status<CR>
$TEMPERATURE = status<CR>
$AVM = status<CR>
status = { FAULT, OK }
4.2 TRIGGER STATUS
Request the on/off status of the input trigger.
4.2.1
Query:
?TRIGSTAT<CR>
4.2.2
Response:
For trigger ON:
$TRIGIN = ON<CR>
For trigger OFF:
$TRIGIN = OFF<CR>
4.3 OUTLET STATUS
Request the on/off status of the outlets.
4.3.1
Query:
?OUTLETSTAT<CR>
4.3.2
Response:
$OUTLET1 =
status
<CR>
$OUTLET2 =
status
<CR>
$OUTLET3 =
status
<CR>
$OUTLET4 =
status
<CR>
$OUTLET5 =
status
<CR>
$OUTLET6 =
status
<CR>
$OUTLET7 =
status
<CR>
$OUTLET8 =
status
<CR>
status
= { ON, OFF }
4.4 POWER STATUS
Request the status of the input voltage.
4.4.1
Query:
?POWERSTAT<CR>
4.4.2
Response: if input voltage is
within limits:
$PWR = NORMAL<CR>
during overvoltage:
$PWR = OVERVOLTAGE<CR>
during undervoltage:
$PWR = UNDERVOLTAGE<CR>
during recovery:
$PWR = RECOVERY<CR>
RS-232 and Telnet Command Set / Protocol Specifications
(Continued)
PLEASE NOTE:
Zero in the First Position
before the comma (0,)
equates to
ALWAYS OFF
.
Zero in the Second Posi-
tion after the comma (,0)
equates to
ALWAYS ON
.