2.Important Information on Blood Pressure 
and its Measurement    

2.1. How does high or low blood pressure arise?

Your level of blood pressure is determined in the circulatory center of the brain 
and adjusts to a variety of situations through feedback from the nervous 
system. To adjust blood pressure, the strength and speed of the heart (Pulse), 
as well as the width of circulatory blood vessels is altered.Blood vessel width 
is controlled by fine muscles in the blood vessel walls.
Your level of arterial blood pressure changes periodically during heart activity: 
During the “blood ejection” (Systole) the value is highest (systolic blood 
pressure value). At the end of the heart’s “rest period” (Diastole) pressure is 
lowest (diastolic blood pressure value).

2.2. Which values are normal?

Please refer to the diagram below(Picture-01)

Note:

This device contains sensitive electronic components. Avoid 
strong electrical or electromagnetic fields in the direct vicinity of 
the device (e.g. mobile telephones, microwave ovens) during use. 
These can lead to erratic results.

Note:

Do not attempt to service or repair this device yourself. Should a 
malfunction occur, refer to local distributor or the manufacturer.

Caution:

To avoid damaging the device, keep this unit away from children 
and pets.

Caution:

The standard material used for the bladder and tubing is latex-free.

Attention:

Self-measurement means control, not diagnosis or treatment. 
Unusual values must always be discussed with a 

physician

Under no circumstances should you alter the dosages of any 
drugs prescribed by a 

physician

.

Attention:

The pulse display is not suitable for checking the frequency of 

heart pacemakers!

Attention:

In cases of irregular heartbeat, measurements made with this 
instrument should only be evaluated after consultation with a 

physician

.

Note:

To obtain the greatest accuracy from your blood pressure 
instrument, it is recommended that the instrument be used within 
the specified temperature and the relative humidity, please see 
the Technical Specifications.

Note:

The cuff is treated as the applied part.The user should contact 
the manufacturer for assistance, if needed, in setting up, using 
or maintaining the device.

Summary of Contents for B63

Page 1: ...oad Guihua community Guanlan town Longhua new district 518100 Shenzhen PEOPLE S REPUBLIC OF CHINA Shanghai International Holding Corp GmbH Europe Eiffestrasse 80 20537 Hamburg Germany Panacare Officia...

Page 2: ...ure and its Measurement 3 Components of Your Blood Pressure Monitor 4 Using Your Monitor for the First Time 5 Measurement Procedure 6 Care and Maintenance 7 Warranty service 8 Certifications 9 Technic...

Page 3: ...this manual Warning The separate ac adapter which is intended to connect USB interface of Blood Pressure Monitor has not been evaluated according to IEC 60601 1 The safety of the product shall be reap...

Page 4: ...microwave ovens during use These can lead to erratic results Note Do not attempt to service or repair this device yourself Should a malfunction occur refer to local distributor or the manufacturer Cau...

Page 5: ...f 3 Average value function 5 Built in chargeable lithium battery 7 Cuff and main unit are integrated as one part 2 One user 120 sets memory 4 Irregular heartbeat checking 6 Low battery display 1 Heart...

Page 6: ...nt Press the START STOP button again the measurement will stop b Assessment of the memory record Press MEM or MEM button once it will seek for the next previous assessment record c Delete record When...

Page 7: ...xamination but serves to detect pulse irregularities at an early stage 5 4 Irregular Heartbeat Detector 5 3 Measure Procedure Picture 06 Refer to picture 06 The monitor is designed to take measurement...

Page 8: ...ed Abnormal measurement results The cuff is too loose Pressure fluctuation is large when measuring The pressure exceeds the upper limit Abnormal or uncalibrated calibration data Authorized Representat...

Page 9: ...ff with bladder must not be washed in a dishwasher clothes washer or submerged in water c Do not drop the monitor or treat it roughly in any way Avoid strong vibrations d Never open the monitor This i...

Page 10: ...c fields near the unit This may result in incorrect operation of the unit 3 Caution This unit has been thoroughly tested and inspected to assure proper performance and operation 4 Caution this machine...

Page 11: ...ironment NOTE UT is the a c mains voltage prior to application of the test level Guidance and manufacture s declaration electromagnetic immunity Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 10...

Page 12: ...ce d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitte...

Page 13: ...nde Guihua Stadt Guanlan neuer Bezirk Longhua 518100 Shenzhen VOLKSREPUBLIK CHINA Shanghai International Holding Corp GmbH Europa Eiffestra e 80 20537 Hamburg Deutschland Panacare Official outlook com...

Page 14: ...formationen zum Blutdruck und dessen Messung 3 Komponenten des Blutdruckmessger ts 4 Monitor zum ersten Mal verwenden 5 Messverfahren 6 Pflege und Wartung 7 Garantie Service 8 Zertifizierungen 9 Techn...

Page 15: ...tur oder Feuchtigkeitsbedingungen au erhalb der im Abschnitt Spezifikationen dieses Handbuchs angegebenen Grenzen betrieben oder gelagert wird Achtung Das separate Netzteil zum Anschluss der USB Schni...

Page 16: ...t latexfrei Vorsicht Selbstmessung bedeutet Kontrolle nicht Diagnose oder Behandlung Ungew hnliche Werte m ssen immer mit einem Arzt besprochen werden Unter keinen Umst nden sollten Sie die Dosierung...

Page 17: ...lwertfunktion 4 berpr fung des unregelm igen Herzschlags 5 Eingebaute aufladbare Lithiumbatterie 6 Anzeige f r schwache Batterie 7 Manschette und Haupteinheit sind als ein Teil integriert 1 Heartbeat...

Page 18: ...g wird gestoppt b Speicherdaten Dr cken Sie die Taste MEM oder MEM einmal um nach dem n chsten vorherigen Bewertungsdatensatz zu suchen c Datensatz l schen Wenn Sie nach Speicherdatens tzen suchen Hal...

Page 19: ...hrt und die Messwerte im Speicher speichert 1 Setzen Sie sich bequem auf einen Stuhl mit den F en flach auf dem Boden 2 Dr cken Sie die START STOP Taste um die Messung zu starten Strecken Sie Ihren A...

Page 20: ...zschlag erkannt oder Blutdruck berechnet Abnormale Messergebnisse Die Manschette ist zu locker Die Druckschwankung ist beim Messen gro Der Druck berschreitet den oberen Messbereich Abnormal oder unkal...

Page 21: ...ntfernt werden Die Manschette mit Blase darf nicht in einer Sp lmaschine oder Waschmaschine gewaschen oder in Wasser getaucht werden c Lassen Sie den Monitor nicht fallen und behandeln Sie ihn in kein...

Page 22: ...ationen Modell B63 Gewicht 240 2 g Kein Netzteil im Lieferumfang enthalten Anzeige 30 58mm 2 28 x1 18 LCD Digitalanzeige Gr e 120 B x 66 L x 30 H mm 4 72 B x2 6 L x1 18 H Zubeh r 1 Hauptger t 1 Benutz...

Reviews: