© Pan Acoustics GmbH
V 1.0
Page 20 of 22
Manual
Via the Dante audio network of the manufacturer Audinate Pty Ltd. it is possible to activate the pre-
sets via UDP commands.
Calling up presets String (HEX)
Preset 1
50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 31 1c 30 32 30 32 0d
Preset 2
50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 32 1c 30 32 30 33 0d
Preset 3
50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 33 1c 30 32 30 34 0d
Preset 4
50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 34 1c 30 32 30 35 0d
Preset 5
50 41 4e 41 43 4f 55 53 54 49 43 53 02 46 46 46 45 52 1c 30 35 1c 30 32 30 36 0d
General information
The following control commands must be transmitted completely. The timing indicated below must be
taken into account. There is no feedback. All Pan Beam loudspeakers in the audio network execute
the command.
Timing
A waiting time of at least 3 s must be adhered to between the individual commands.
Network address and port
Address: 224.0.1.4
Port: 4712
17.4.9. Dante media controller
Each Pan Beam loudspeaker has an alarm contact.
The loudspeaker can indicate a detected error via
this alarm contact. For this purpose, a switch relay
is installed in the loudspeaker, which is closed in
normal operating status. If the loudspeaker is not
in operation, if there is no power supply or if an
internal error is signalled via the DSP, the relay is
opened.
Pan Beam loudspeakers connected to a Dante net-
work also have this function. This function can be
used via the Pan Net Link interface. For this pur-
pose, the loudspeaker must be connected to an
appropriate interface, e.g. Pan Con, via the Pan Net
Link interface by means of a network cable. Via the
alarm contact on the Pan Con interface, the alarm
contact status can then be monitored by means
of a GPI on the media controller.
17.4.8. Alarm contact (alarm loop) in connection with Dante
18. Technical data
For technical data of the products mentioned in this manual, see the latest data sheets of the prod-
ucts. These are available on the Pan Acoustics website under “Downloads”.
Pan Beam
Alarm
USB
PWR
Pan Con 485