Paloma PJC-W18FR Installation Instructions Manual Download Page 9

 

 

Do  not  use  this  heater  in  areas  where  spray  painting  is  taking  place  or  in  areas  such  as  hairdressers 
where there may be lots of fluff and dust or where aerosols may be used. 

 

All replacement parts must be approved Paloma spare parts. 

 

This  heater  may  circulate  large  volumes  of  air.  If  the  air  in  the  room  contains  any  cigarette  smoke  or 
cooking vapours, it may affect the appearance of carpets, furniture and drapes, etc.  

 

Clean the air filter regularly (at least once a week). 

 
 
 
 
 
 
 
 

 

Do not move the heater during operation. 

 

Do not use for any other purpose other than for heating. Must only be used as a space heater. 

 

Do not touch the  warm air outlet during operation.  Supervise  young children or infirm persons  near the 
heater. Also ensure that children do not play with this appliance. 

 

Do not sit, stand or lean on the heater. 

 

Do not insert your fingers into the louvres or the air inlet of the heater. 

 

Do  not  cut  the  electrical  cord  to  extend  the  lead.  Install  the  heater  where  the  original  electrical  cord 
reaches a wall socket. 

 

Do not unplug or shut down during operation. This may cause overheating. 

 

Do not place the heater near an opening door. The heater could be knocked over.  

 

Do not touch the electric plug with wet hands as this could cause an electric shock. 

 

Do not pull the electrical cord to unplug as this could break the cord and start a fire. 

 

Place  a  flat  board  for  stability  when  placing  the  heater  on  soft  or  thick  carpet.  Placing  directly  on  to  a 
carpet may discolour the carpet. 

 

Ensure that recommended clearances are maintained at all times. 

 

This  heater  is  designed  for  domestic  household  applications  only.  Using  this  heater  in  commercial 
applications will shorten its life significantly.  

 

In case of thunderstorms, cease operation and unplug the electrical cord. 

 

Do not use sprays containing silicon in the vicinity of the heater. It damages the oxygen depletion safety 
device. 

 

Do not install in a place where the heater may be affected by wind. The flame could be blown out by a 
strong wind. 

 

Do not place articles on or against or in front of warm air outlet or air filter of this appliance. 

 

If the heater is shut off by the oxygen depletion safety system, please ensure you ventilate the room 
immediately for satisfactory combustion.  

 

Prior to operation of the unit please ensure that the gas hose is removed from the holding clips, uncoiled 
and installed into your bayonet fitting without any kinks in the hose.  
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Caution 

Summary of Contents for PJC-W18FR

Page 1: ...be installed in accordance with a Local Gas Fitting Regulations b Municipal Building Codes c Australian Standard for Gas Appliance Installations AS5601 2004 d Any other relevant Statutory Regulation...

Page 2: ...components supplied by the manufacturer It does not apply to components supplied by others Where a failed component is replaced under warranty the balance of the original appliance warranty will remai...

Page 3: ...rrying the heater Warning Label Rating Plate Shows model No Gas Type Month of Manufacture Warm Air Inlet Warm air is discharged Louvre Air Filter 1 Prevents dust entering the appliance Gas Hose Electr...

Page 4: ...e correctly fitted 3 Replace access panel and gently push into position TIMER1 BUTTON TIMER2 BUTTON TEMPERATURE ADJUSTMENT BUTTON OVER RIDE BUTTON CHILD LOCK LIGHT ON OFF BUTTON FILTER LIGHT SET TIMES...

Page 5: ...e heater Low Emission Technology Class 1 Appliance AS4553 2008 Less than half the emissions of the Australian Standard Energy efficient 7 stage modulating gas valve Manufactured in Japan Safety Device...

Page 6: ...Capacity Maximum Sq m 97 70 Minimum Room Sizing Cu M 62 5 45 Test Point Pressure NG kPa 0 86 0 47 LPG kPa 2 0 1 2 Test Point Pressure at Turndown NG kPa 0 13 0 13 LPG kPa 0 3 0 3 Injector Sizes NG mm...

Page 7: ...red by the Victorian Building Act 1993 Only a licensed person will give you a compliance certificate showing that the work complies with all relevant standards Only a licensed person will have insuran...

Page 8: ...correctly ventilated while unit is operating Continuous use decreases the oxygen level in the room which activates the oxygen depletion safety system Do not allow curtains or other flammable materials...

Page 9: ...ter near an opening door The heater could be knocked over Do not touch the electric plug with wet hands as this could cause an electric shock Do not pull the electrical cord to unplug as this could br...

Page 10: ...er Do not install where water may splash or near another heat source Do not install in a caravan mobile home or recreational vehicle Do not connect to a Propane LPG gas cylinder indoors This appliance...

Page 11: ...e temperatures inside the heater and is normal Please do not unplug the heater while the fan is still operating Important Information When using the heater for the first time or after long periods of...

Page 12: ...uttons For Eg Select 22 Degrees C as your desired temperature and this temperature is then memorised into the control system SET temperature selection can range from 16 Degrees C low 26 Degrees C high...

Page 13: ...peration is switched OFF Over ride light glows ON OFF light glows green and timers are ready After the heater turns off the convection fan will continue to operate for up to 4 minutes Do not unplug wh...

Page 14: ...or 11 12am 1 Adjust the hour Keep pressing the adjustment button until 11 00am is displayed 2 Adjust the minute Press the adjustment button again until 11 12am is displayed Press SET TIMES five times...

Page 15: ...ime press the down or up button until the correct time is reached Example To set the TIMER 1 ON time to 5 30AM 1 Adjust the hour 2 Keep pressing the adjustment button until 5 00AM is displayed 3 Adjus...

Page 16: ...adjustment button until 8 10PM is displayed Press SET TIMES button TIMER 2 OFF light flashes TIMER 2 OFF time is displayed on the screen Adjust TIMER 2 OFF time as required To set the TIMER 2 OFF time...

Page 17: ...lete the process Press The TIMER1 and or TIMER 2 button s as follows You can select TIMER 1 or TIMER 2 or both by pressing the TIMER 1 and or TIMER 2 buttons Selected TIMER s ON OFF lights will glow T...

Page 18: ...ock the air outlet Press the TIMER S button s You can select TIMER 1 or TIMER 2 or both by pressing the TIMER 1 and or TIMER 2 buttons Selected TIMER s ON OFF lights will glow The TIMER operation is n...

Page 19: ...e timers are overlapped the time that is set first will have priority and the timer set second will be cancelled The timer settings will continue to operate if they are not cancelled PRE HEAT FUNCTION...

Page 20: ...stops after the temperature inside the heater has cooled No action required The heater creaks at the time of lighting or switching off The sound is caused by expansion and contraction of metallic part...

Page 21: ...lem persists call for service The gas supply volume is inadequate Call for a licensed plumber Thermo switch is off Call for service Air Filter is clogged Clean Air Filter and operate again If problem...

Page 22: ...2 Air filter is fitting correctly and is not dirty 3 The hose is correctly connected without kinking or twisting 4 There is no damage to the electric cord Maintenance Caution Wear gloves Be careful of...

Page 23: ...ashes clean Air Filters 1 and 2 Use a vacuum cleaner to remove dirt on the Air Filters Air Filter 1 could be taken off to clean Use mild soapy water for severe dirt and refit after drying If Air Filte...

Page 24: ...4961 3515 03 9212 8911 08 8343 0044 08 9351 4290 Parts Fax 07 3412 9219 02 9684 9188 02 4961 3117 03 9212 8984 08 8359 6003 08 9351 4614 Service Email qld service rhee m com au nsw service rhee m com...