SVC 820-Tankless Gas Trouble Shooting Manual Page |
81
81
71 – Error Code Diagnostic Chart
YES
NO
While unit is attempting to go to ignite,
check DC voltage across yellow and black
wires on Molex connector “K”:
75 – 100 DC VOLTS
Is the DC voltage
OK?
Attempt to operate again.
If the unit malfunctions due to an Error
Code 71:
Replace Control Board
Reset the water heater and attempt to operate again.
If the unit malfunctions due to an Error Code 71:
Replace Gas Control Valve
Summary of Contents for PH2-20R OFN
Page 158: ...158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Page 159: ...159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Page 160: ...160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Page 162: ...162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Page 163: ...163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Page 164: ...164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Page 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166...
Page 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167...
Page 169: ...169 Schematic Disassembly PHH 32ROF PHH 25ROF...