Page SVC 820 Tankless Gas Trouble Shooting Manual
54
16 – Error Code
Explanation:
Outlet water temperature is too hot. The
water temperature is above the set point on Remote
Control.
Check the Outlet Thermistor FIRST.
Diagnostic Checks:
1.
Outlet Thermistor
2.
Water Bypass Valve
OUTLET WATER TEMPERATURE SENSOR DIAGNOSTICS:
Turn power OFF. Remove connector “R” on Control
Board. Measure resistance between Black #3 & red
#4 wires: 7K – 23K Ohms. IF OK, attempt to operate
unit again. IF 16 Error Code does NOT display, unit
had a loose connection.
IF resistance tested OK and 16 Error Code IS
displayed, go to Error Code 66 for Water Bypass Valve
diagnostics. IF resistance NOT OK, go to step 2.
Turn power OFF. Remove 3 screws for Control Board
mounting bracket. Remove connectors “M”, “T” &
“G”. Pull control board out of way to access BLACK
Molex for Outlet Thermistor located near the Blower
Motor.
1
2
3
Control Board
Bottom of Unit
Screws
Molex Connectors
Outlet Thermistor
Separate top and bottom of BLACK
Molex for Outlet Thermistor. Top of
Molex has 2 black wires and 1 red
wire. Bottom of Molex has 2 black
wires. Continue to diagnostic chart
on next page.
Summary of Contents for PH2-20R OFN
Page 158: ...158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Page 159: ...159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Page 160: ...160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Page 162: ...162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Page 163: ...163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Page 164: ...164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Page 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166...
Page 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167...
Page 169: ...169 Schematic Disassembly PHH 32ROF PHH 25ROF...