Connect Power to a PA-220R Firewall
STEP 3 |
Insert the posive DC cable into terminal A+ and secure the cable by turning the flat-head
terminal screw clockwise unl ght. Insert the negave cable into terminal A- and secure the
cable using the terminal screw. Do not torque the terminal screws to more than 2 in-lbs.
STEP 4 |
(
Oponal
) Repeat step 3 to connect a second DC power source to terminals B+ and B-.
STEP 5 |
Plug the cabled DC terminal block into the DC inputs on the firewall. Secure the terminal
block by turning the two screws on each side of the block clockwise and torque to 3 in-lbs.
STEP 6 |
Power on the DC power source to power on the firewall. The firewall powers on and the
power (PWR) LED turns green.
PA-220R Next-Gen Firewall Hardware Reference
30
©