background image

Installation

Installation Kit Included (find in carton)

2

1. Make sure power supply breaker is switched off. Installation must be carried out in accordance  with
    the current edition of the local wiring regulations code having jurisdiction. Installation should be
    performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark
    locations of 4 mounting holes and wire service entry at knockout (KO) location.
    

Note: 

For two or more dryers,  dryers should be no closer than 24 inches (610 mm) on center.

3. Remove and retain 2 cover screws and cover.
4. a. 

For in-wall (concealed) power supply - (See MT & IG 1207101509) 

        

Provide supply wire to KO location according to local code and attach securely to chassis at KO

        with appropriate strain relief connector (not supplied).
    b. 

For Surface Mounted Conduit (exposed) power supply - 

        Provide appropriate conduit to entry location according to local code and attach securely to chassis
        with correct strain relief connector (not supplied).
5. Drill four (4) holes at locations A, B, C and D of  Ø5/16" (Ø8) Diameter x 1-3/8" (35mm) deep if using
    wall anchors supplied with unit. Install supplied anchors flush with wall face, or install other fastening
    system suitable for wall conditions (not supplied). Attach dryer to wall. For wood wall/studs use Ø1/4
    inch (M6) screws at length that will ensure 1 inch (25 mm) min. stud penetration. For masonry walls
    use expansion bolts or anchors for Ø1/4 inch (M6) screws  to ensure penetration 1/4 inch (6 mm)
    deeper than anchor. Shim if necessary to ensure base plate is flat against wall.
6. Connect supply and ground wires to terminal block where indicated or connect supply wires to
    terminal block where indicated and connect ground wire to base plate with ground screw.
                                                                   

 Connections:

      

A

. Connect the live wire (colored Brown, Red or Black) to the terminal block marked "L".

      

B

. Connect the neutral wire (colored Black, Blue, White or Grey) or connect the second live wire

           (colored Red or Orange) to the terminal block marked "N".
      

C

. Connect the ground wire to the terminal block marked "    " or to the green screw marked "    ".

           Bare grounding (earth) wires should be sleeved with green and yellow or green tubing.
    Colors of live and neutral wires depend on voltage of supply service and requirements of Building
    and Electrical Code having jurisdiction.
7. Replace cover. Do not over-tighten screws. 

 

 

Service Tool Included (with installation kit)

Security hex driver 4 mm x 1 pcs (5/32" pin-hex will work if tool is lost)
Please unpack the unit and check the quantity of the above tool and kit. 

Operating Instructions and Parts Manual 

Hand Dryer

Surface-mounted 

ADA

-compliant hand dr yer 

VAC

110

115

120

208

220

230

240

277

Motor 

Heater 

Vac

110

115

120

208

220

230

240

240

Inrush A(W)

5.73 (630)

5.99 (689)

6.25 (750)

2.71 (563)

2.86 (630)

2.99 (689) 

3.13 (750)

3.13 (750)

Operating  A (W)

3.82 (420)

3.99 (459)

4.17 (500)

1.81 (376)

1.91 (420)

2.00 (459)

2.08 (500)

2.08 (500)

3.82 (420)

3.99 (459)

4.17 (500)

1.81 (376)

1.91 (420)

2.00 (459) 

2.08 (500)

2.08 (500)

Vac

110

115

120

208

220

230

240

240

Total

Inrush A(W)

9.55 (1050)

9.98 (1148)

10.42 (1250)

4.51 (939)

4.77 (1050) 

4.99 (1148) 

5.21 (1250)

5.21 (1250)

Operating A(W)

7.64 (840)

7.99 (918)

8.33 (1000)

3.61 (751)

3.82 (840) 

3.99 (918) 

4.17 (1000)

4.17 (1000)

Input

Inrush / Operating A(W)

1. Self-Threading screws 1/4" x 1-1/2" (M6 x 38)  x 4 pcs           4. Crimp-on terminal wire tip x 3 pcs
2. Metal Washer 3/8" x 7/8"x 1/16" (Ø10 x Ø22 x 1.6 thk) x 4 pcs
3. Nylon bushing x 4 pcs                  

5. Plastic anchor Ø5/16" x 1-3/8" 
    (Ø8 x 35) x 4 pcs                  

distributed by 

 RESTROOM DIRECT       704 . 937. 2673      

www.

RestroomDirect

.com

All manuals and user guides at all-guides.com

Summary of Contents for BLUSTORM BOLT

Page 1: ...Fixture Company P O Box 10887 Green Bay WI 54307 1 800 558 8678 www palmerfixture com uto A distributed by RESTROOM DIRECT 704 937 2673 www RestroomDirect com All manuals and user guides at all guide...

Page 2: ...e Adjustable by Owner 325 450 W Auto Resetting Thermostat turns heater element off at 185 F 85 C Resets at 167 F 75 C Thermal cut off at 288 F 142 C Less than 15 seconds Infrared Automatic self adjust...

Page 3: ...to terminal block where indicated and connect ground wire to base plate with ground screw Connections A Connect the live wire colored Brown Red or Black to the terminal block marked L B Connect the n...

Page 4: ...ryer automatically starts operation Rub hands lightly and rapidly under the nozzle Dryer stops when hands are removed from sensor zone or if maximum time is reached Operating Instructions and Parts Ma...

Page 5: ...ect the power and remove the dryer cover and replace CBM IR sensor module First ensure that the breaker supplying the dryer is operational If it is disconnect the power and remove the dryer cover Repl...

Page 6: ...mounted ADA compliant hand dryer 5 1 2 3 4 5 6 7 8 9 10 11 13 12 14 15 16 17 18 19 20 21 22 Tools Req d Provided in kit L Wrench Item 23 distributed by RESTROOM DIRECT 704 937 2673 www RestroomDirect...

Page 7: ...Sensor module Terminal block Rubber grommet Base Mylar shield with LNG marked Cable clamp Grounding screw with cup washer Cable protector Base plate Cover BluStorm Bolt Stainless steel Satin Security...

Reviews: