background image

1

ITEM CATEGORY

Operating Voltage

Output Warm Air Volume 

Output Warm Air Temp 

Output Air Speed

Sound Pressure

Motor Type

Motor Thermal Protection

Heater Element

Heater Thermal Protection

Drying Time

Circuit Operation

Sensor Range

Timing Protection

Timing Duration

Cover Type

Cover Finish

Net Weight

Shipping Weight

Unit Size

PERFORMANCE DATA

TECHNICAL SPECIFICATIONS

110-120 VAC, 50/60 Hz, 1.0kW

80 m³/h

131°F {55°C} at ambient T = 77°F {25°C}, MAX, Adjustable by Owner

95-115 m/s 

 

76.2 dB-A Max @ 1M

0.67 HP, 16 - 29 krpm, Adjustable, Brush Type, Dual Ball Bearings

120 VAC, Auto Resetting Thermostat turns unit off at 275°F {135°C}

ON/ OFF Heating options; Range Adjustable by Owner, 325 - 450 W 

Auto Resetting Thermostat turns heater element off at 185°F {85°C}, Resets at 

167°F {75°C},Thermal cut-off at 288°F {142°C}

Less than 15 seconds

Infrared Automatic, self adjusting

Standard 7" {172 ± 20} mm

60 seconds auto shut off

2 seconds delayed turn off after last sensor read

18 gauge {.047", 1.2 mm} thick drawn steel or 304 series stainless steel

Satin on stainless steel

8.4 lbs {3.8 kg}

9.2 lbs {4.2 kg}

10-9/16" W x 5-63/64" H x 3-15/16” D {268 x 152  x 100}

DIM’S

inch(mm)

MODEL # BluSTORM BOLT

5-63/64

 

  

(152)

3-15/16

 

(

100)

10-9/16

  

(268

)

Operating Instructions and Parts Manual 

Hand Dryer

Surface-mounted 

ADA

-compliant hand dr yer 

220-240 VAC, 50/60 Hz, 1.0kW

240 VAC, Auto Resetting Thermostat turns unit off at 203°F {95°C}

distributed by 

 RESTROOM DIRECT       704 . 937. 2673      

www.

RestroomDirect

.com

Summary of Contents for BluSTORM BOLT

Page 1: ...PALMER FIXTURE COMPANY Palmer Fixture Company P O Box 10887 Green Bay WI 54307 1 800 558 8678 www palmerfixture com uto A distributed by RESTROOM DIRECT 704 937 2673 www RestroomDirect com...

Page 2: ...FF Heating options Range Adjustable by Owner 325 450 W Auto Resetting Thermostat turns heater element off at 185 F 85 C Resets at 167 F 75 C Thermal cut off at 288 F 142 C Less than 15 seconds Infrare...

Page 3: ...or connect supply wires to terminal block where indicated and connect ground wire to base plate with ground screw Connections A Connect the live wire colored Brown Red or Black to the terminal block m...

Page 4: ...under the nozzle and dryer automatically starts operation Rub hands lightly and rapidly under the nozzle Dryer stops when hands are removed from sensor zone or if maximum time is reached Operating In...

Page 5: ...roblem persists disconnect the power and remove the dryer cover and replace CBM IR sensor module First ensure that the breaker supplying the dryer is operational If it is disconnect the power and remo...

Page 6: ...and Parts Manual Hand Dryer Surface mounted ADA compliant hand dryer 5 1 2 3 4 5 6 7 8 9 10 11 13 12 14 15 16 17 18 19 20 21 22 Tools Req d Provided in kit L Wrench Item 23 distributed by RESTROOM DIR...

Page 7: ...bracket Sensor bracket Sensor module Terminal block Rubber grommet Base Mylar shield with LNG marked Cable clamp Grounding screw with cup washer Cable protector Base plate Cover BluStorm Bolt Stainles...

Reviews: